APC Smart-UPS RT 3000VA 230V - SURTD3000XLIM | price in dubai UAE Africa saudi arabia

APC Smart-UPS RT 3000VA 230V Marine – SURTD3000XLIM

For The Immediate delivery contact the sales team. Usually, Ship in 2-3 days, back order ship in 4-12 Weeks, images are for illustration purposes only.

AED. 12,325.00 excl. VAT

Best Price: AED. 12,016.88 on Bank Transfer / Cash Payment (-AED. 308.13)
Estimated delivery between Apr 27, 2024 - May 30, 2024
3 + 1 =
SKU: SURTD3000XLIM Category: Tags: , ,

APC Smart-UPS RT 3000VA 230V Marine – SURTD3000XLIM

Green Premium™ RoHS
APC Smart-UPS RT 3000VA 230V - Marine

 

 

Overview

 

SURTD3000XLIM Features

Run time for load

12m 55s

Max. Capacity Used

100%
Output power capacity

2.1kWatts / 3.0kVA
Rack Height

3U
Output Connections

(2) IEC Jumpers (Battery Backup)
(2) IEC 320 C19 (Battery Backup)
(8) IEC 320 C13 (Battery Backup)
Nominal Output Voltage

230V
Nominal Input Voltage

230V
Input Connections

BS1363A British, IEC 60320 C20, Schuko CEE 7 / EU1-16P
Cord Length

2.4meters
APC Smart-UPS RT 3000VA 230V - Marine

APC Smart-UPS RT 3000VA 230V – Marine

High density, double-conversion on-line power protection with scalable runtime.
Includes: CD with software, Relay board, Smart UPS signalling RS-232 cable, User manual

Smart-UPS On-Line Features & Benefits

Manageability

LED status indicators

Quickly understand unit and power status with visual indicators.
Network manageable

Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
Serial connectivity

Provides management of the UPS via a serial port.
InfraStruXure Manager Compatible

Enables centralized management via the APC InfraStruXure Manager.
Intelligent Card Slot

Customize UPS capabilities with management cards.

Availability

Automatic internal bypass

Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.
Scalable runtime

Allows additional run time to be quickly added as needed.
Automatic restart of loads after UPS shutdown

Automatically starts up the connected equipment upon the return of utility power.
Temperature-compensated battery charging

Prolongs battery life by regulating the charge voltage according to battery temperature.
Hot-swappable batteries

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Protection

Power conditioning

Protects connected loads from surges, spikes, lightning, and other power disturbances.
Resettable circuit breaker

Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Cold-start capable

Provides temporary battery power when the utility power is out.
Frequency and voltage regulation

Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Generator compatible

Ensures clean, uninterrupted power to protected equipment when generator power is used.
Input power factor correction

Minimizes installation costs by enabling the use of smaller generators and cabling.

Adaptability

Flash upgradeable firmware

Install maintenance releases of firmware remotely using FTP.
Plug-and-Play external batteries

Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertible

Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

Marketing features

Peace of mind that comes with full equipment compatibility and reliability of a leader

Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
Avoids costly power problems by keeping your IT equipment and data protected and available .

Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
Save time with easy and convenient remote/network accessibility.

Network manageable via serial, USB or Ethernet. Includes Powerchute® Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
Low operating and maintenance costs with proven reliability and intelligent battery management .

Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.

Serviceability

Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Disconnected battery notification

Warns when a battery is not available to provide backup power.
Audible alarms

Provides notification of changing utility power and UPS power conditions
Predictive failure notification.

Provides early-warning fault analysis ensuring proactive component replacement.
User-replaceable batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
APC Smart-UPS RT 3000VA 230V - Marine

 

Detailed Tech Specification

 

Output

Max Configurable Power (Watts)

2.1kWatts / 3.0kVA
Output Voltage Note

Configurable for 220 : 230 or 240 nominal output voltage
Output Voltage Distortion

Less than 3 %
Output Frequency (sync to mains)

50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz Sync to mains
Other Output Voltages

220 V, 240 V
Load Crest Factor

3 : 1
Topology

Double conversion online
Waveform type

Sine wave
Bypass

Internal bypass (automatic and manual)

Input

Input frequency

50/60 Hz +/- 5 Hz Auto-sensing
Input voltage range for main operations

180 – 270V
Number of Power Cords

1
Other Input Voltages

220 V, 240 V

Batteries & Runtime

Battery type

Lead-acid battery
Included Battery Modules

2
Typical recharge time

2.5hour(s)
Replacement Battery

Expected Battery Life (years)

3 – 5
RBC Quantity

1
Battery Charge Power (Watts)

359 Watts
Extendable Run Time

1

Communications & Management

Interface Port(s)

RJ-45 Serial, Smart-Slot
Pre-Installed SmartSlot™ Cards

Control panel

LED status display with load and battery bar-graphs and on line : on battery : replace battery : overload and bypass indicators
Audible Alarm

Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Emergency Power Off (EPO)

Yes

Surge Protection and Filtering

Surge energy rating

555Joules
Filtering

Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449

Physical

Maximum Height

432MM, 43.2CM
Maximum Width

130MM, 13.0CM
Maximum Depth

660MM, 66.0CM
Net Weight

54.55KG
Shipping weight

63.64KG
Shipping Height

347MM, 34.7CM
Shipping Width

603MM, 60.3CM
Shipping Depth

980MM, 98.0CM
Color

Black
Units per Pallet

6.0

Environmental

Operating Temperature

0 – 55 °C
Operating Relative Humidity

0 – 95 (Non-condensing) %
Operating Elevation

0 – 3048meters
Storage Temperature

-15 – 45 °C
Storage Relative Humidity

0 – 95 (Non-condensing) %
Storage Elevation

0 – 15240meters
Audible noise at 1 meter from surface of unit

55.0dBA
Online thermal dissipation

609.0BTU/hr
Protection Class

IP20

Conformance

Approvals

CE, DNV, EN 50091-1, EN 50091-2, EN 55022 class A, EN 60950, EN 61000-3-2, KCC
Standard warranty

2 years repair or replace, optional extended warranties available, optional on-site services available

Sustainable Offer Status

RoHS

Compliant
PEP

Available in Documentation tab
EOLI

Available in Documentation tab
Proposition 65 Warning

Available in Documentation tab