Rack PDU 2G Switched ZeroU 11kW 230V (21) C13 & (3) C19 – AP8981

 Green Premium™

 

 

Rack PDU 2G, Switched, 11kW, 230V, (21) C13 & (3) C19 (BEING DISCONTINUED - SEE APDU9981NA3, APDU9981EU3)

 

 

Overview

 

AP8981 Features

Output Connections

(21) IEC 60320 C13
(3) IEC 60320 C19

Nominal Output Voltage

208V, 230V

Nominal Input Voltage

400V 3PH

Input Connections

IEC 60309 16 A 3P + N + PE, IEC 60309 20 A 3P + N + PE

Cord Length

1.8meters

Rack PDU 2G, Switched, 11kW, 230V, (21) C13 & (3) C19 (BEING DISCONTINUED – SEE APDU9981NA3, APDU9981EU3)

APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. The output and input connections are (21) C13 & (3) C19, and the cable length is 3m. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low-profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and are complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager, and Change Manager.
Includes: Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable

NetShelter Switched Rack PDUs Features & Benefits

Availability

Field-replaceable NMC

Integrated Network Management Card/Display Module can be replaced in the field to minimize downtime disruption in the unlikely event of a failure.

C13/C15 and C19/C21 Hybrid Outlets

Available on select 9000 series PDUs only, Industry 1st hybrid outlets allow 60C operating temperature at full load, are fully compatible with standard C14 and C20 power cords, and are future proofed for implementation of higher temperature rated devices requiring C16 and C21 power cords.

Hydraulic Magnetic Circuit Breakers

Provide increased availability by maintaining trip current over a wide temperature range.

High Retention Outlets

With no special power cords required, high retention outlets provide up to twice the holding force to reduce risk of accidental disconnect on 9000 series PDUs.

60C Operating Temperature

All 8000 and 9000 series PDUs now provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today’s high density deployments. Other models allow up to 45C (113F).

Agility

Flash Upgradeable

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Adaptability

Single input power source

Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Rack-Mountable

Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most – in the racks near the equipment.

Wide range of input and output connections

Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip.

Manageability

EcoStruxure IT Ready

Seamless integration of one or many PDUs including alerts and control with EcoStruxure IT. Allows IT and data center professionals to monitor and manage all of their critical IT infrastructure on-premise, in the cloud, and at the edge from anywhere.

Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Gigabit Ethernet Connectivity

9000 series PDUs provide Gigabit Ethernet to enhance and standardize network connectivity across all assets in the data center. All other models provide 10/100 ethernet connectivity.

Enhanced Cybersecurity

9000 series PDUs include APC Network Management card with security features including secured interfaces and a modified password policy providing peace of mind.

Multi-tier user access

Supports up to four access levels – Administrator, Device User, Read-Only User and Network-only User – with user name and password requirements.

Network Port Sharing

Connect and manage multiple PDUs from one IP address to simplify and speed deployment while saving the cost required in having a dedicated network connection for each PDU. Manage up to 32 PDUs with 9000 series and up to 4 PDUs with 8000 series.

Network Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Outlet Level Grouping

Outlet power sequencing can be configured to group any combination of outlets to power up or down together providing flexibility.

Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

1% Metering Accuracy

Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use these PDUs to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Available on 9000 series PDUs.

 

Rack PDU 2G, Switched, 11kW, 230V, (21) C13 & (3) C19 (BEING DISCONTINUED - SEE APDU9981NA3, APDU9981EU3)


 

 

Detailed Tech Specification

 

Output

Overload Protection

No

Maximum Total Current Draw

16

Input

Input frequency

50/60 Hz

Number of Power Cords

1

Load Capacity

11000VA

Maximum Input Current

16A

Maximum Line Current

16A

Regulatory Derated Input Current (North America)

16A

Physical

Maximum Height

1791MM, 179.1CM

Maximum Width

56MM, 5.6CM

Maximum Depth

46MM, 4.6CM

Net Weight

7.0KG

Shipping weight

8.95KG

Shipping Height

2002MM, 200.2CM

Shipping Width

165MM, 16.5CM

Shipping Depth

114MM, 11.4CM

Color

Black

Units per Pallet

48.0

Environmental

Operating Temperature

-5 – 60 °C

Operating Relative Humidity

5 – 95 %

Operating Elevation

0 – 3048meters

Storage Temperature

-25 – 65 °C

Storage Relative Humidity

5 – 95 %

Storage Elevation

0 – 15240meters

Conformance

Approvals

cUL listed, EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC part 15 class A, ICES-003, UL listed, VDE

Standard warranty

2 years repair or replace

Sustainable Offer Status

RoHS

Compliant

PEP

Available in Documentation tab

EOLI

Available in Documentation tab