APC Symmetra LX 12kVA scalable to 16kVA N+1 Tower - SYA12K16I | price in dubai UAE Africa saudi arabia

APC Symmetra LX 12kVA scalable to 16kVA N+1 Tower 220/230/240V or 380/400/415V – SYA12K16I

For The Immediate delivery contact the sales team. Usually, Ship in 2-3 days, back order ship in 4-12 Weeks, images are for illustration purposes only.

AED 54,941.00 excl. VAT

Best Price: AED 53,567.48 on Bank Transfer / Cash Payment (-AED 1,373.53)
Estimated delivery between Jan 28, 2025 - Feb 13, 2025
3 + 3 =
SKU: SYA12K16I Category: Tags: , ,

APC Symmetra LX 12kVA scalable to 16kVA N+1 Tower 220/230/240V or 380/400/415V – SYA12K16I

RoHS
APC Symmetra LX 12kVA scalable to 16kVA N+1 Tower, 220/230/240V or 380/400/415V

Overview

 

SYA12K16I Features

Run time for load

7m 32s

Max. Capacity Used

100%

Output power capacity

8.4kWatts / 12.0kVA

Output Connections

(1) Hard wire 3-wire (H N + E) (Battery Backup)

Nominal Output Voltage

230V

Nominal Input Voltage

230V, 400V 3PH

Input Connections

Hard wire 3-wire (1P + N + E), Hard wire 5-wire (3P + N + E)

APC Symmetra LX 12kVA scalable to 16kVA N+1 Tower, 220/230/240V or 380/400/415V

High performance, redundant power protection with scalable power and runtime for space-constrained server rooms, and voice and data networks.
Includes: CD with software, Documentation CD, Installation guide, User manual, Web/SNMP management card
  • Removable input/output wiring tray
    Allows quick and easy installation and maintenance of the UPS.

Symmetra Features & Benefits

Availability

Automatic restart of loads after UPS shutdown

Automatically starts up the connected equipment upon the return of utility power.

Battery modules connected in parallel

Delivers higher availability through redundant batteries.

Automatic internal bypass

Supplies utility power to the connected loads in the event of a UPS power overload or fault.

Power Modules connected in parallel

Enhances availability by allowing immediate, seamless recovery from isolated module failures.

Redundant Intelligence Modules

Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.

Hot-swappable power modules

Ensures clean, uninterrupted power to protected equipment during Power Module replacement.

Modular design

Provides scalability, N+1 redundancy, fast serviceability, and reduced maintenance requirements via self-diagnosing, swappable, and field-replaceable modules.

Hot-swappable intelligence modules

Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.

Configurable for N+1 internal redundancy

Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

Hot-swappable batteries

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Manageability

Intelligent Card Slot

Customize UPS capabilities with management cards.

LCD display

Alpha-Numeric Display which displays system parameters and alarms.

InfraStruXure Manager Compatible

Enables centralized management via the APC InfraStruXure Manager.

Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Manageable external batteries

Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.

Network manageable

Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.

Marketing features

Avoids costly power problems by keeping your IT equipment and data protected and available .

Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.

Peace of mind that comes with complete equipment compatibility and reliability of a market leader .

Safety agency tested and approved means that you can deploy Symmetra with confidence that they meet or exceed the industry’s most rigorous standards.

Save time with easy and convenient remote accessibility.

Network manageable via serial, USB or optional Ethernet. Includes Powerchute® Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.

Low operating and maintenance costs with proven reliability and intelligent battery management .

Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.

Modular, Scalable, Redundant Architecture future proof initial investment, improves equipment availability, and simplifies maintenance.

Symmetra LX’s redundant N+1 architecture enables the unit to withstand a failures of an intelligence module, battery or power module. Modules are easily replaceable in the field. Customers can add additional power modules or batteries after initial equipment purchase to accommodate loads of up to 16 kVA.

Protection

Generator compatible

Ensures clean, uninterrupted power to the loads in the event of an extended power outage

Input power factor correction

Minimizes installation costs by enabling the use of smaller generators and cabling.

Cold-start capable

Provides temporary battery power when the utility power is out.

Frequency and voltage regulation

Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Resettable circuit breakers

Enables a quick recovery from overload events.

Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Power conditioning

Protects connected loads from surges, spikes, lightning, and other power disturbances.

Scalability

Scalable runtime

Allows additional run time to be quickly added as needed.

Programmable frequency

Ensures compatibility with different input frequencies.

Scalable power capacity

Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.

Field-replaceable power distribution panel

Ensures compatibility with equipment that has different plug types.

Plug-and-Play external batteries

Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.

Serviceability

Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Disconnected battery notification

Warns when a battery is not available to provide backup power.

Audible alarms

Provides notification of changing utility power and UPS conditions.

User-replaceable power modules

Enables simple upgrades and replacements of the Power Modules.

User-replaceable batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

User-replaceable intelligence modules

Enables simple upgrades and replacements of the Intelligence Modules.

Predictive failure notification.

Provides early-warning fault analysis ensuring proactive component replacement.
APC Symmetra LX 12kVA scalable to 16kVA N+1 Tower, 220/230/240V or 380/400/415V

Detailed Tech Specification

 

Output

Max Configurable Power (Watts)

11.2kWatts / 16.0kVA

Output Voltage Note

Configurable for 220 : 230 or 240 nominal output voltage

Output Voltage Distortion

Less than 5 % at full load

Output Frequency (sync to mains)

47 – 63 Hz Sync to mains, 50 Hz +/- 0.1 % For 50 Hz nominal Unsynchronised, 60 Hz +/- 0.1 % For 60 Hz nominal Unsynchronised

Other Output Voltages

220 V, 240 V

Load Crest Factor

Up to 5 : 1

Topology

Double conversion online

Waveform type

Sine wave

Maximum Output Current

55

Bypass

Internal bypass (automatic and manual)

Input

Input frequency

45 – 65 Hz Auto-sensing

Input voltage range for main operations

155 – 276, 290 – 480 3:1V

Input Total Harmonic Distortion

Less than 7 % for full load

Other Input Voltages

220 V, 240 V, 380 V, 415 V

Input Power Factor at Full Load

0.98

Batteries & Runtime

Battery type

Lead-acid battery

Included Battery Modules

3

Typical recharge time

3hour(s)

Replacement Battery

Battery Slots Empty

1

Expected Battery Life (years)

3 – 5

Battery Charge Power (Watts)

861 Watts

Extendable Run Time

1

Communications & Management

Interface Port(s)

DB-9 RS-232, RJ-45 10/100 Base-T, Smart-Slot

Pre-Installed SmartSlot™ Cards

Control panel

Multifunction LCD status and control console

Audible Alarm

Audible and visible alarms prioritized by severity

Emergency Power Off (EPO)

Yes

Available SmartSlot™ Interface Quantity

1

Physical

Maximum Height

937MM, 93.7CM

Maximum Width

483MM, 48.3CM

Maximum Depth

726MM, 72.6CM

Net Weight

263.64KG

Shipping weight

287.27KG

Shipping Height

1181MM, 118.1CM

Shipping Width

599MM, 59.9CM

Shipping Depth

997MM, 99.7CM

Color

Black, Silver

Units per Pallet

1.0

Environmental

Operating Temperature

0 – 40 °C

Operating Relative Humidity

0 – 95 %

Operating Elevation

0 – 3048meters

Storage Temperature

-15 – 45 °C

Storage Relative Humidity

0 – 95 %

Storage Elevation

0 – 4572meters

Audible noise at 1 meter from surface of unit

62.0dBA

Online thermal dissipation

3707.0BTU/hr

Conformance

Approvals

C-Tick, CE, EN 50091-1, EN 50091-2, EN 55022 class A, EN 55024, EN 60950, GOST, IEC 60950, VDE

Standard warranty

2 years repair or replace

Sustainable Offer Status

RoHS

Compliant

Reviews

There are no reviews yet.

Be the first to review “APC Symmetra LX 12kVA scalable to 16kVA N+1 Tower 220/230/240V or 380/400/415V – SYA12K16I”