Rack PDU 2G, Metered, ZeroU, 30A, 100-120V, (24) 5-20R - AP8832 Price in Dubai UAE

Rack PDU 2G, Metered, ZeroU, 30A, 100-120V, (24) 5-20R – AP8832

For Immediate delivery requirement contact sales team. Ex-Stock Usually Ship in 1 -3 days, Back to Back 4-8 Weeks. Images are for illustration purposes only and may differ from actual product.

AED 2,713.00 excl. VAT

Best Price: AED 2,645.18 on Bank Transfer / Cash Payment (-AED 67.82)
6 + 1 =
SKU: AP8832 Category: Tag:

Rack PDU 2G, Metered, ZeroU, 30A, 100-120V, (24) 5-20R – AP8832

 

 

Overview

 

AP8832Features

Rack PDU 2G, Metered, ZeroU, 30A, 100-120V, (24) 5-20R

  • Vertical Mounting Capabilities
    Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures.

Metered Rack PDUFeatures & Benefits

Availability
  • Integrates with StruxureWare Data Center Expert
    An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
  • Load indicator LED
    Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
  • Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
  • Local Current Monitoring Display
    The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
  • Remote Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Marketing Features
  • Wide range of input and output connections
    Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • Local and web-based monitoring
    Status available to customers both in the data center and remotely
  • Local Current Monitoring Display
    The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
  • Load indicator LED
    Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Agility
  • Wide range of input and output connections
    Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
  • Rack-Mountable
    Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most – in the racks near the equipment.
  • Single input power source
    Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

 

Detailed Tech Specification

 

Output

  • Nominal Output Voltage

    100V , 120V

  • Overload Protection

    Yes

  • Output Connections
    (24) NEMA 5-20R (Battery Backup)

Input

  • Nominal Input Voltage

    100V , 120V

  • Input frequency

    50/60 Hz

  • Input Connections

    NEMA L5-30P

  • Cord Length

    3meters

  • Acceptable Input Voltage

    100-120VAC

  • Number of Power Cords

    1

  • Load Capacity

    2880VA

  • Maximum Input Current

    30A

  • Regulatory Derated Input Current (North America)

    24A

Physical

  • Maximum Height

    1791mm , 179.1CM

  • Maximum Width

    55mm , 5.5CM

  • Maximum Depth

    44mm , 4.4CM

  • Net Weight

    6.67KG

  • Shipping weight

    8.58KG

  • Shipping Height

    2006mm , 200.6CM

  • Shipping Width

    164mm , 16.47CM

  • Shipping Depth

    108mm , 10.83CM

  • Color

    Black

Environmental

  • Operating Temperature

    -5 – 45 °C

  • Operating Relative Humidity

    5 – 95 %

  • Operating Elevation

    0-3000meters

  • Storage Temperature

    -25 – 65 °C

  • Storage Relative Humidity

    5 – 95 %

  • Storage Elevation

    0-15000meters

Conformance

  • Approvals

    cUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL 60950-1, UL Listed

  • Standard warranty

    2 years repair or replace

Sustainable Offer Status

  • RoHS

    Compliant

  • REACH

    REACH: Contains No SVHCs

  • Battery Directive

    Compliant

  • Battery Notes

    ts_Battery_Notes

Reviews

There are no reviews yet.

Be the first to review “Rack PDU 2G, Metered, ZeroU, 30A, 100-120V, (24) 5-20R – AP8832”