Overview
BR900G-RS Features
Run time for load
4m 36s
Max. Capacity Used
Output power capacity
540 Watts / 900VA
Output Connections
(2) Schuko CEE 7 (Surge Protection)
(3) Schuko CEE 7 (Battery Backup)
Nominal Output Voltage
230V
Nominal Input Voltage
230V
Input Connections
Schuko CEE 7/7P
Cord Length
1.5meters
Maximum Input Current
8.0A
APC Back-UPS Pro 900, 900VA, 230V, AVR, 5 CIS outlets (2 surge)
High Performance Computer and Electronics UPS for Premium Power Protection
- Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
- Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
- Audible alarms
Provides notification of changing utility power and UPS power conditions
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Automatic Voltage Regulation (AVR)
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
- Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
- Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
- Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
- Cold-start capable
Provides temporary battery power when the utility power is out.
- Data-line Protection
Protection against powers spikes traveling through data lines ensures complete protection of your equipment from surges. It is very important to protect your equipment from “back door” surges traveling through data lines, as they can be as damaging to your equipment as surges traveling over power lines.
- Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
- Disconnected battery notification
Warns when a battery is not available to provide backup power.
- Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
- LCD display
Manage the UPS locally through a text-based display that allows quick diagnosis via stored alarm conditions and events.
- LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
- Power-saving outlets
Automatically cuts power to idle equipment to conserve electricity.
- Replace Battery LED
An external Replace Battery LED informs the end-user that the battery needs to be replaced.
- Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
- Serial connectivity
Provides management of the UPS via a serial port.
- USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Back-UPS Pro Features & Benefits
Manageability
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Availability
Customizable voltage sensitivity
Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
Customizable voltage-transfer points
Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Cold-start capable
Provides temporary battery power when the utility power is out.
Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.
Protection
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes .
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Marketing features
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
Serviceability
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Simple battery replacement
Increases UPS availability by allowing quick, easy battery replacement.
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Detailed Tech Specification
Output
Max Configurable Power (Watts)
540 Watts / 900VA
Output Frequency (sync to mains)
50/60 Hz +/- 1 Hz Unsynchronised, 50/60 Hz +/- 3 Hz Sync to mains
Topology
Line interactive
Waveform type
Stepped approximation to a sinewave
Transfer Time
8 ms typical : 10 ms maximum
Input
Input frequency
50/60 Hz +/- 3 Hz Auto-sensing
Input voltage range for main operations
156 – 300 Adjustable, 176 – 294V
Batteries & Runtime
Battery type
Lead-acid battery
Typical recharge time
8hour(s)
Replacement Battery
Expected Battery Life (years)
3 – 5
RBC Quantity
1
Battery Charge Power (Watts)
20 Watts
Runtime
Efficiency
Communications & Management
Interface Port(s)
Optional Simple Signalling RS232 cable, USB
Control panel
Multifunction LCD status and control console
Surge Protection and Filtering
Surge energy rating
613Joules
Data Line Protection
RJ11 modem/fax/DSL protection (two wire single line), RJ45 10/100 Base-T Ethernet protection
Physical
Maximum Height
100MM, 10.0CM
Maximum Width
250MM, 25.0CM
Maximum Depth
382MM, 38.2CM
Net Weight
10.72KG
Shipping weight
12.4KG
Shipping Height
487MM, 48.7CM
Shipping Width
225MM, 22.5CM
Shipping Depth
337MM, 33.7CM
SCC Codes
10731304295683
Environmental
Operating Temperature
0 – 40 °C
Operating Relative Humidity
0 – 95 %
Operating Elevation
0 – 3048meters
Storage Temperature
-15 – 45 °C
Storage Relative Humidity
0 – 95 %
Storage Elevation
0 – 15240meters
Audible noise at 1 meter from surface of unit
45.0dBA
Conformance
Approvals
GOST
Standard warranty
2 years repair or replace
Sustainable Offer Status
RoHS
Compliant
PEP