APC NetShelter SX 48U Deep Enclosure - AR3307 | price in dubai UAE Africa saudi arabia

APC NetShelter SX 48U 600mm Wide x 1200mm Deep Enclosure with Sides Black – AR3307

For The Immediate delivery contact the sales team. Usually, Ship in 2-3 days, back order ship in 4-12 Weeks, images are for illustration purposes only.

AED. 10,777.00 excl. VAT

Best Price: AED. 10,507.58 on Bank Transfer / Cash Payment (-AED. 269.42)
Estimated delivery between May 8, 2024 - Jun 4, 2024
6 + 2 =
SKU: AR3307 Category: Tag:

APC NetShelter SX 48U 600mm Wide x 1200mm Deep Enclosure with Sides Black – AR3307

 

 

APC Netshelter SX, Server Rack Enclosure, 48U, Black, 2258H x 600W x 1200D mm

 

 

Overview

 

AR3307 Features

Rack Height

48U
Rack Width

19″
APC Netshelter SX, Server Rack Enclosure, 48U, Black, 2258H x 600W x 1200D mm

APC Netshelter SX, Server Rack Enclosure, 48U, Black, 2258H x 600W x 1200D mm

An industry-standard server rack ready for medium to high-density environments with height designed to easily fit through standard doorways. A deeper rack design provides enough rack mounting space for even the deepest devices and still plenty of room for vertically mounting Rack PDUs and cable management. 48U height allows for an additional 6U of rack mounting space maximizing u-space per rack footprint.
Includes: Baying hardware, Key(s), Leveling feet, Mounting hardware, Pre-installed casters, Side panels

APC Netshelter SX, Server Rack Enclosure, 48U, Black, 2258H x 600W x 1200D mm

NetShelter SX Enclosures Features & Benefits

Agility

Adjustable mounting rails with captive hardware and rapid alignment

The vertical mounting rails can be adjusted in 1/4 in (6.4 mm) increments covering virtually any mounting requirement for IT equipment. Easy alignment feature integrated into the enclosure mounting rail and side brace for quick alignment verification without the use of tools to verify alignment. U positions are numbered front and back for rapid installation of equipment.
Integrated joining hardware with multiple width enclosure alignment

Enclosures include pre-installed joining hardware to join enclosures in a row and provide additional stability to the enclosure. The pre-installed joining hardware includes holes for joining to an adjacent enclosure at 600mm centers or 24in centers depending upon the floor layout.
Enclosure assemble-to-order (ATO) options capable

The Enclosure ATO (Assemble-to-Order) options provide a level of customization for enclosure customers beyond the standard enclosure models. This customization is limited to the assembly of the enclosure itself and does not include additional enclosure mounted components. For example, the enclosure can be assembled without sides, doors, or without sides and doors. Check apc.com for enclosure size options and availability.
Pre-installed full-enclosure height rear accessory channels

Integrated and adjustable rear accessory channel provides zero U mounting locations for toolless accessories. Each channel has two mounting bays to support a combination of up to four accessories such as PDUs and vertical cable organizers. 1070mm (42in), 825mm (32 in), and deep enclosures and networking enclosures include two channels. 1200mm (48in) deep enclosures include four channels. Channels are pre-installed at the factory in the rear of the enclosure but can be moved to other locations of the enclosure along the side brace to resituate cable management where it is needed most.
Low-profile castors and adjustable leveling feet from underneath or above

Enclosures are shipped standard with both leveling feet and castors. Leveling feet can be quickly adjusted through the use of a screwdriver or drill, eliminating the need to reach underneath with a wrench.
Split rear doors

Split rear doors improve access and serviceability to rear of rack mounted equipment. The split rear doors help to maximize floor space. Only 11 inches (279 mm) of clearance is required behind the enclosures to allow for door swing.
Special packaging options for shipping rack with equipment pre-racked

Enclosures with shock packaging are standard enclosures with provisions in the packaging design and enclosure assembly for shipping the enclosures with equipment mounted inside. Extensive industry experience with the leading IT manufacturers and most recently certified with Cisco® for pre-racking and shipping Cisco Unified Computing Systems (UCS). Check apc.com for enclosure size options and availability.

Compatiblity

Optimized for high capacity cable management systems

NetShelter SX enclosures are optimized for use with high capacity cable management systems that attach to equipment mounting rails inside enclosures aligning with equipment mounting u-spaces and provide channels for routing and managing cabling.
Integrated with InfraStruxure products

Schneider Electric cooling, power distribution, and cable management products work seamlessly with IT enclosures to provide a complete infrastructure support system.
Vendor-neutral EIA-310 19in Rack Mounting Compatibility Guaranteed

Vendor-neutral mounting for guaranteed compatibility with all EIA-310 compliant 19″ equipment. The “Fits Like a Glove” money back guarantee provides peace of mind that all of your EIA-310-E compliant rack-mount equipment will physically fit in a NetShelter.
Schneider Electric Rack Systems Compatible

Compatible with a variety of Schneider Electric rack accessory products to provide the ability to create a complete rack system. Configure rack solutions using industry leading Schneider Electric Design Portal – Small IT Solution Designer configurator complete with verification of product compatibility and useful 3rd party equipment catalog to aid in visualizing your ideal rack solution.

Convenience

Perforated front door with curved profile

Perforated front and rear doors provide ample ventilation for servers and networking equipment. Front door perforated area is optimized with a curved profile to provide greater surface area and allowance of more perforation coverage and higher perforation rating.
Eyebolt support integrated into enclosure frame

Integrated eyebolt holes at the top of the enclosure frame allow the enclosure to be lifted for movement and enclosure placement using eyebolt lifting mechanisms. Refer to enclosure user documentation for detailed specifications on eyebolt requirements and enclosure weight limits.
Half-height side panels and option with brush strips for pass-through

Half-height quick release side panels reduce size and weight for easy handling and access to equipment. Side panels are lockable utilizing a single key with the doors. Now available are side panel options integrated with pass-through holes and brush strips for routing cabling to adjacent racks in a row while still maintaining proper airfow.
Enclosure adjustment tools and hardware provided

All enclosures are provided standard with hardware bag that includes hardware for mounting IT equipment and tools for simple enclosure adjustment.
Equipment mounting rails integrate with patch cabling systems

Equipment mounting rails include zero U mounting holes beside the EIA 19″ mounting space that allow the installation of Data Distribution Cable (DDC) patch systems without taking up any critical equipment U-space. AV and Networking enclosure designs do not include hole locations for integration of DDC cabling. Other 1U, 2U, and rear enclosure zero U options are available for use with these enclosures.
Cable access openings with pre-installed brushes

Large cable access slots in the roof provides access for overhead cable egress. The bottom design allows for unobstructed cable access through a raised floor. Roof includes openings with brush strips pre-installed in locations biased towards the front of the enclosure to allow for data cable passthrough and provisions for air containment.
Easily removable cable access roof

Roof can be removed with simple pull-pin hinges for access during equipment installation or even with cabling already in place and routed through the cable openings. Once removed the roof is reversible to reposition the larger cable openings for power distribution plugs and connectors.
Quick release doors

Front door can be moved to the opposite side or interchanged with rear doors. Doors are easily removed with simple lift-off design.
Simple Selection

No need to spend hours choosing from and compiling dozens of part numbers to create a single enclosure. Schneider Electric has made it easy by handling the details and providing complete enclosures with single part numbers.

Safety

Integrated electrical grounding

The roof, side panels and front and rear doors are grounded to the frame of the enclosure. Eight additional electrical grounding inserts are located on the frame for external grounding.
Load Capacity

A proven frame design, heavy-gauge mounting rails, and heavy-duty casters provide for a 3750 lb (1700 kg) static (levelling feet) and 2250 lb (1023 kg) dynamic (castor) load ratings (42U-52U). The 12U and 18U have a static and dynamic load capacity of 600 and 900 pounds (272/408kgs) respectively. Enclosures have been tested and approved to be combined with proper bolt down accessories to meet various seismic requirements. Check apc.com for product documentation for specific requirements
APC Netshelter SX, Server Rack Enclosure, 48U, Black, 2258H x 600W x 1200D mm

 

Detailed Tech Specification

 

Physical

Maximum Height

2258MM, 225.8CM
Maximum Width

600MM, 60.0CM
Maximum Depth

1200MM, 120.0CM
Net Weight

149.55KG
Shipping weight

165.45KG
Shipping Height

2385MM, 238.5CM
Shipping Width

752MM, 75.2CM
Shipping Depth

1334MM, 133.4CM
Color

Black
Maximum Mounting Depth

1060.0MM, 105.99CM
Minimum Mounting Depth

191.0MM, 19.1CM
Front Door

16.0gauge
Vertical Posts

16.0gauge
Rear Door

18.0gauge
Roof

18.0gauge
Side Panels

18.0gauge
Units per Pallet

1.0
Weight Capacity (static load)

1700.97KG
Weight Capacity (dynamic load)

1020.58KG

Environmental

Protection Class

IP20

Conformance

Approvals

EIA-310E, UL 2416, UL 60950-1
Standard warranty

5 year repair or replace

Sustainable Offer Status

RoHS

Compliant
PEP

Available in Documentation tab
EOLI

Available in Documentation tab