APC Rack PDU 2G Metered by Outlet - AP8641 | price in dubai UAE Africa saudi arabia

APC Rack PDU 2G Metered by Outlet with Switching ZeroU 30A 200/208V (21) C13 & (3) C19 sockets – AP8641

For Immediate delivery requirement contact sales team. Ex-Stock Usually Ship in 1 -3 days, Back to Back 4-8 Weeks. Images are for illustration purposes only and may differ from actual product.

AED 8,359.00 excl. VAT

Best Price: AED 8,150.03 on Bank Transfer / Cash Payment (-AED 208.98)
Estimated delivery between Nov 21, 2024 - Dec 12, 2024
0 + 9 =
SKU: AP8641 Category: Tags: ,

APC Rack PDU 2G Metered by Outlet with Switching ZeroU 30A 200/208V (21) C13 & (3) C19 sockets – AP8641

 

 

APC Rack PDU, 2G, metered by outlet, with switching, 0U, 30A, 200V and 208V, 21 C13 and 3 C19 sockets

 

 

Overview

AP8641 Features

Output Connections

(3) IEC 60320 C19
(21) IEC 60320 C13

Nominal Output Voltage

200V, 208V

Nominal Input Voltage

200V, 208V, 230V

Input Connections

NEMA L6-30P

Cord Length

3meters

APC Rack PDU, 2G, metered by outlet, with switching, 0U, 30A, 200V and 208V, 21 C13 and 3 C19 sockets

APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
Includes: CAN port terminator, Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable
  • Metering-by-Outlet capability
    Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.

NetShelter Metered-by-Outlet with Switching Rack PDU Features & Benefits

Availability

Flash Upgradeable

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Network Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Metering-by-Outlet capability

Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.

Remote Individual Outlet Control

Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Outlet Power Sequencing

Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Local Current Monitoring Display

The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Load indicator LED

Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. (Note: Only available with units with local current monitoring feature)

Integrates with StruxureWare Data Center Expert

An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Agility

Single input power source

Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
APC Rack PDU, 2G, metered by outlet, with switching, 0U, 30A, 200V and 208V, 21 C13 and 3 C19 sockets

 

 

Detailed Tech Specification

 

Output

Overload Protection

Yes

Maximum Total Current Draw

30

Input

Input frequency

50/60 Hz

Acceptable Input Voltage

200 – 240VAC

Number of Power Cords

1

Load Capacity

4992VA

Maximum Input Current

30A

Maximum Line Current

30A

Regulatory Derated Input Current (North America)

24A

Physical

Maximum Height

1829MM, 182.9CM

Maximum Width

56MM, 5.6CM

Maximum Depth

51MM, 5.1CM

Net Weight

8.23KG

Shipping weight

10.5KG

Shipping Height

2038MM, 203.8CM

Shipping Width

162MM, 16.2CM

Shipping Depth

118MM, 11.8CM

Color

Black

Units per Pallet

48.0

Environmental

Operating Temperature

-5 – 60 °C

Operating Relative Humidity

5 – 95 %

Operating Elevation

0 – 3048meters

Storage Temperature

-25 – 65 °C

Storage Relative Humidity

5 – 95 %

Storage Elevation

0 – 15240meters

Conformance

Approvals

cUL listed, FCC part 15 class A, ICES-003, PSE, UL listed, VCCI class A

Standard warranty

2 years repair or replace

Sustainable Offer Status

RoHS

Compliant

Reviews

There are no reviews yet.

Be the first to review “APC Rack PDU 2G Metered by Outlet with Switching ZeroU 30A 200/208V (21) C13 & (3) C19 sockets – AP8641”