Overview
SURTD2200XLIM Features
Run time for load
21m 17s
Max. Capacity Used
Output power capacity
1.54kWatts / 2.2kVA
Rack Height
3U
Output Connections
(2) IEC 60320 C19 (Battery Backup)
(8) IEC 60320 C13 (Battery Backup)
(2) IEC Jumpers (Battery Backup)
Nominal Output Voltage
230V
Nominal Input Voltage
230V
Input Connections
BS1363A British, IEC 60320 C20, Schuko CEE 7 / EU1-16P
Cord Length
2.5meters
APC Smart-UPS RT 2200VA 230V – Marine
High availability, ruggedized power protection for shipboard and other transportation applications.
Includes: CD with software, Documentation CD, Installation guide, Rack mounting hardware, Smart UPS signalling RS-232 cable, User manual
- Advanced electrical features
Excellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high power efficiency
- Audible alarms
Provides notification of changing utility power and UPS power conditions
- Automatic internal bypass
Pure static bypass switch without bridging contactor securing a fast and reliable transfer to and from bypass, rated for 125% nominal load.
- Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Disconnected battery notification
Warns when a battery is not available to provide backup power.
- Double conversion on-line topology
Guarantees a consistently high level of power quality. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
- Excellent footprint
Small UPS footprint provides maximum usage of valuable electrical room floorspace
- Fast battery charging capability
Allows for reduced battery recharge time, prevents disturbances on the distribution system by correcting the power factor, protects the battery against damage caused by deep discharge and provides backfeed protection.
- Field-replaceable power distribution panel
Ensures compatibility with equipment that has different plug types.
- Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
- Front-access servicing
Simplifies installation and UPS maintenance while minimizing space requirements.
- Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
- Global safety approvals
UL60950, CSA60950, IEC60950, EN60950 safety approvals. Meets IEC 61000-4-5 Immunity To Surge, and GR-1089-CORE, Section 4, Lightning and AC Power Faults standards.
- High online efficiency
Reduces utility costs, generates less heat.
- Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
- Intelligent Battery Charging
Microprocessor controlled, 3-stage regulated charging ensures the fastest recharge times without decreasing battery life.
- Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
- Intuitive monitoring
Step by step navigation and menu screens for critical system information and data. Information is easy to access and presented in a very intuitive way.
- LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
- Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
- Overload protection
Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload.
- Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
- Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
- Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
- Programmable frequency
Ensures compatibility with different input frequencies.
- Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
- Remote UPS management
Enable management of your UPS by connecting it directly to the network.
- Safety-agency approved
The UPS is UL1778 Listed
- Scalable runtime
Allows additional run time to be quickly added as needed.
- Serial connectivity
Provides management of the UPS via a serial port.
- Sine wave output
Eliminates humming and heat generated when powering tube lights and fans
- Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
- Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
- User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Wide input voltage range
Designed for harsh electrical environments to save battery life.
Marine Features & Benefits
Availability
Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Serviceability
Easy to install
Innovative design allows for fast, easy installation by almost anybody.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Technical support
Our experienced technical support engineers are available to answer your questions, giving you peace of mind knowing the help you need is there when you need it.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Manageability
Intelligent Card Slot
Customize UPS capabilities with management cards.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Serial connectivity
Provides management of the UPS via a serial port.
Detailed Tech Specification
Output
Max Configurable Power (Watts)
1.54kWatts / 2.2kVA
Output Voltage Note
Configurable for 220 : 230 or 240 nominal output voltage
Output Voltage Distortion
Less than 3 %
Output Frequency (sync to mains)
50 Hz +/- 0.1 % For 50 Hz nominal Unsynchronised, 50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz Sync to mains, 60 Hz +/- 0.1 % For 60 Hz nominal Unsynchronised
Other Output Voltages
220 V, 240 V
Load Crest Factor
3 : 1
Topology
Double conversion online
Waveform type
Sine wave
Bypass
Internal bypass (automatic and manual)
Input
Input frequency
50/60 Hz +/- 5 Hz Auto-sensing
Input voltage range for main operations
180 – 280V
Number of Power Cords
1
Other Input Voltages
220 V, 240 V
Batteries & Runtime
Battery type
Lead-acid battery
Included Battery Modules
2
Typical recharge time
2.5hour(s)
Replacement Battery
Expected Battery Life (years)
3 – 5
RBC Quantity
1
Battery Charge Power (Watts)
382 Watts
Extendable Run Time
1
Runtime
Communications & Management
Interface Port(s)
RJ-45 Serial, Smart-Slot
Pre-Installed SmartSlot™ Cards
Control panel
LED status display with load and battery bar-graphs and on line : on battery : replace battery : overload and bypass indicators
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Emergency Power Off (EPO)
Yes
Surge Protection and Filtering
Surge energy rating
555Joules
Filtering
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Physical
Maximum Height
432MM, 43.2CM
Maximum Width
130MM, 13.0CM
Maximum Depth
660MM, 66.0CM
Net Weight
54.55KG
Shipping weight
63.64KG
Shipping Height
347MM, 34.7CM
Shipping Width
603MM, 60.3CM
Shipping Depth
980MM, 98.0CM
Color
Black
Units per Pallet
6.0
Environmental
Operating Temperature
0 – 55 °C
Operating Relative Humidity
0 – 95 (Non-condensing) %
Operating Elevation
0 – 3048meters
Storage Temperature
-15 – 45 °C
Storage Relative Humidity
0 – 95 (Non-condensing) %
Storage Elevation
0 – 15240meters
Audible noise at 1 meter from surface of unit
55.0dBA
Online thermal dissipation
609.0BTU/hr
Protection Class
IP20
Conformance
Approvals
CE, DNV, EN 50091-1, EN 50091-2, EN 55022 class A, EN 60950, EN 61000-3-2, KCC
Standard warranty
2 years repair or replace, optional extended warranties available, optional on-site services available
Sustainable Offer Status
RoHS
Compliant
PEP