APC Symmetra PX 100kW Scalable to 250kW - SY100K250D | price in dubai UAE Africa saudi arabia

APC Symmetra PX 100kW Scalable to 250kW without Maintenance Bypass or Distribution- Parallel Capable – SY100K250D

For The Immediate delivery contact the sales team. Usually, Ship in 2-3 days, back order ship in 4-12 Weeks, images are for illustration purposes only.

AED 368,699.00 excl. VAT

Best Price: AED 359,481.53 on Bank Transfer / Cash Payment (-AED 9,217.47)
Estimated delivery between Nov 25, 2024 - Jan 21, 2025
1 + 4 =
SKU: SY100K250D Category: Tags: , ,

APC Symmetra PX 100kW Scalable to 250kW without Maintenance Bypass or Distribution- Parallel Capable – SY100K250D

 

 

Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable


 

Overview

 

SY100K250D Features

Run time for load

7m 5s

Max. Capacity Used

100%

Output power capacity

100.0kWatts / 100.0kVA
Output Connections

(1) Hard wire 4-wire (3P + E) (Battery Backup)
(1) Hard wire 5-wire (3P + N + E) (Battery Backup)
Nominal Output Voltage

400V 3PH, 480V 3PH
Nominal Input Voltage

400V 3PH, 480V 3PH
Input Connections

Hard wire 4-wire (3P + E), Hard wire 5-wire (3P + N + E)
Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable

Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable

A high-performance, 3-phase, modular, scalable, power protection solution with industry-leading efficiency, capacity, and performance for medium to large data centers and mission-critical environments. Multiple UPSs can be installed in parallel for ultra-efficient system redundancy or up to 2MW of power protection. Parallel installations with custom switchgear and installations using a 3rd-party maintenance bypass panel require the APC Symmetra PX250/500 Third Party Switchgear Kit for breaker monitoring and EPO functionality.
Includes: Assembly service, Network management card, Start-up service, User manual
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Battery failure notification
    Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Battery modules connected in parallel
    Delivers higher availability through redundant batteries.
  • Battery replacement without tools
    Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
  • Dual mains input
    Increases availability by allowing the UPS to be connected to two separate power sources.
  • ECO Mode
    Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
  • Front-access servicing
    Simplifies installation and UPS maintenance while minimizing space requirements.
  • Intelligent battery management
    Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • LCD graphics display
    Text and mimic diagrams that display modes of operation, system parameters and alarms.
  • Mega Tie
    During maintenance procedures, maintain full protection by transferring the load from one independent Symmetra PX 250/500kW system to another.
  • Output synchronization to external source
    UPS systems can be synchronized with any other independent source for use with downstream static transfer switches.
  • Parallel-capacity capability
    Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
  • Parallel-redundant capability
    Powers the connected equipment with multiple uninterruptible power supplies and redundant fan design to increase system redundancy.
  • Remote Display
    Download the display interface to your laptop or personal computer. Remotely monitor the UPS and configure a sub-set of UPS parameters. Note: Remote start-up and shutdown are not supported.
  • Scalable runtime
    Allows additional run time to be quickly added as needed.
  • Supports 3rd party maintenance bypass
    The APC Symmetra PX250/500 Third Party Switchgear Kit is required for installations with custom switchgear or a 3rd-party maintenance bypass panel. The boards in this kit monitor the breakers and provide EPO functionality.
  • Swappable batteries
    Allows quick addition of runtime capacity or replacement of existing battery modules. Installed modules are automatically recognized by the system.
  • Temperature-compensated battery charging
    Prolongs battery life by regulating the charge voltage according to battery temperature.

Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable

Symmetra PX Features & Benefits

Agility

Scalable power capacity

Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
Intelligent Card Slot

Customize UPS capabilities with management cards.
Programmable frequency

Ensures compatibility with different input frequencies.

Availability

Swappable power modules

Allows quick addition of power capacity or replacement of existing power modules. Installed modules are automatically recognized by the system.
Power Modules connected in parallel

Enhances availability by allowing immediate, seamless recovery from isolated module failures.
Redundant Intelligence Modules

Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
Modular design

Provides scalability, N+1 redundancy, fast serviceability, and reduced maintenance requirements via self-diagnosing, swappable, and field-replaceable modules.
Network manageable

Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
Battery modules connected in parallel

Delivers higher availability through redundant batteries.
Configurable for N+1 internal redundancy

Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
Automatic internal bypass

Supplies utility power to the connected loads in the event of a UPS power overload or fault.
User-replaceable batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
User-replaceable power modules

Enables simple upgrades and replacements of the Power Modules.

Manageability

Audible alarms

Provides notification of changing utility power and UPS power conditions
Integrates with StruxureWare Data Center Expert

An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
LED status indicators

Quickly understand unit and power status with visual indicators.

Sustainability

EU CoC for UPS

Ensures that UPSs sold in the EU are highly efficient

Total cost of Ownership

Generator compatible

Ensures clean, uninterrupted power to protected equipment when generator power is used.
Input power factor correction

Minimizes installation costs by enabling the use of smaller generators and cabling.
5×8 Start-up service included

Required for full coverage of factory warranty
Fully-rated power kVA equals kW

Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable

Detailed Tech Specification

Output

Max Configurable Power (Watts)

500.0kWatts / 500.0kVA
Output Voltage Distortion

Less than 2 %
Output Frequency (sync to mains)

50 Hz +/- 0.1 % For 50 Hz nominal Unsynchronised, 50 Hz Sync to mains, 60 Hz +/- 0.1 % For 60 Hz nominal Unsynchronised, 60 Hz Sync to mains
Other Output Voltages

415 V
Topology

Double conversion online
Waveform type

Sine wave
Overload Operation

10 minutes at 125% and 60 seconds at 150%
Output Voltage THD

< 2% linear load and < 3% non-linear load
Output Voltage Tolerance

+/- 1% static and +/- 5% at 100% load step
Transfer Time

2 ms typical
Bypass

Built-in static bypass

Input

Input frequency

40 – 70 Hz Auto-sensing
Input voltage range for main operations

340 – 460 (400 V), 408 – 552 (480 V)V
Input Total Harmonic Distortion

Less than 5 % for full load
Type of Input Protection Required

3-pole circuit breaker
Other Input Voltages

415 V
Maximum Short Circuit Withstand (Icw)

50.0kAmps
Input Power Factor at Full Load

0.99

Batteries & Runtime

Battery type

VRLA
Included Battery Modules

7
Typical recharge time

3hour(s)
Nominal Battery Voltage

+/- 288 V
Battery Slots Empty

1
RBC Quantity

6
Battery Charge Power (Watts)

12.056kWatts
Efficiency in Battery Operation

96.5 %
Overload Operation

10 minutes at 125% and 60 seconds at 150%

Communications & Management

Interface Port(s)

SYPX250-500_Parallel
Pre-Installed SmartSlot™ Cards

Control panel

Touch screen LCD user interface
Emergency Power Off (EPO)

Optional
Available SmartSlot™ Interface Quantity

1

Physical

Maximum Height

1991MM, 199.1CM
Maximum Width

2350MM, 235.0CM
Maximum Depth

1070MM, 107.0CM
Net Weight

2267.0KG
Shipping weight

2517.0KG
Shipping Height

2150MM, 215.0CM
Shipping Width

2990MM, 299.0CM
Shipping Depth

1270MM, 127.0CM

Environmental

Operating Temperature

0 – 40 °C
Operating Relative Humidity

0 – 95 %
Operating Elevation

0 – 1015.9meters
Storage Temperature

-15 – 40 °C
Storage Relative Humidity

0 – 95 %
Storage Elevation

0 – 15240meters
Audible noise at 1 meter from surface of unit

54.0dBA
Online thermal dissipation

12378.0BTU/hr
Protection Class

IP20, NEMA 1

Conformance

Approvals

CSA C22.2 No 107.3-05, cUL listed, EN 50091-1, EN/IEC 62040-1-1, EN/IEC 62040-3, EUROBAT, FCC part 15 class A, OSHPD, UL listed, VFI-SS-111
Standard warranty

1 year on-site repair or replace with factory authorized Start-Up

Sustainable Offer Status

Proposition 65 Warning

Available in Documentation tab

Reviews

There are no reviews yet.

Be the first to review “APC Symmetra PX 100kW Scalable to 250kW without Maintenance Bypass or Distribution- Parallel Capable – SY100K250D”