SY128K160H-NB Features

Run time for load

Max. Capacity Used

100%
Output power capacity

128.0kWatts / 128.0kVA
Rack Height

42U
Output Connections

(1) Hard wire 5-wire (3P + N + E) (Battery Backup)
Nominal Output Voltage

230V, 400V 3PH
Nominal Input Voltage

400V 3PH
Input Connections

Hard wire 5-wire (3P + N + E)
Maximum Input Current

236.0A

Symmetra PX 128kW Scalable to 160kW, without Bypass, Distribution, or Batteries, 400V

A high-efficiency, modular 3-phase UPS that offers internal redundancy for your data center requirements. With scalable power, this UPS grows with your data center up to 160kW/kVA. Pair with the Classic Battery Cabinet and the Wall-Mount or 300mm Maintenance Bypass Panel to complete your power protection solution. Please click here for Classic Battery Cabinet runtime information. Suitable for small to medium data centers or individual zones of large data centers.
Includes: Network management card, Start-up service, User manual
  • LCD display
    Manage the UPS locally through a text-based display that allows quick diagnosis via stored alarm conditions and events.

Symmetra PX Features & Benefits

Agility

Scalable power capacity

Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
Intelligent Card Slot

Customize UPS capabilities with management cards.
Programmable frequency

Ensures compatibility with different input frequencies.

Availability

Swappable power modules

Allows quick addition of power capacity or replacement of existing power modules. Installed modules are automatically recognized by the system.
Power Modules connected in parallel

Enhances availability by allowing immediate, seamless recovery from isolated module failures.
Redundant Intelligence Modules

Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
Modular design

Provides scalability, N+1 redundancy, fast serviceability, and reduced maintenance requirements via self-diagnosing, swappable, and field-replaceable modules.
Network manageable

Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
Battery modules connected in parallel

Delivers higher availability through redundant batteries.
Configurable for N+1 internal redundancy

Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
Automatic internal bypass

Supplies utility power to the connected loads in the event of a UPS power overload or fault.
User-replaceable batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
User-replaceable power modules

Enables simple upgrades and replacements of the Power Modules.

Manageability

Audible alarms

Provides notification of changing utility power and UPS power conditions
Integrates with StruxureWare Data Center Expert

An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
LED status indicators

Quickly understand unit and power status with visual indicators.

Sustainability

EU CoC for UPS

Ensures that UPSs sold in the EU are highly efficient

Total cost of Ownership

Generator compatible

Ensures clean, uninterrupted power to protected equipment when generator power is used.
Input power factor correction

Minimizes installation costs by enabling the use of smaller generators and cabling.
5×8 Start-up service included

Required for full coverage of factory warranty
Fully-rated power kVA equals kW

Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.

 

Detailed Tech Specification

 

Output

Max Configurable Power (Watts)

160.0kWatts / 160.0kVA
Neutral Output Current

320A
Output Voltage Note

Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Efficiency at Full Load

95.0 %
Output Voltage Distortion

Less than 2 %
Output Frequency (sync to mains)

50 Hz +/- 0.1 % For 50 Hz nominal Unsynchronised, 50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz Sync to mains
Topology

Double conversion online
Waveform type

Sine wave
Overload Operation

10 minutes at 125% and 60 seconds at 150%
Output Voltage THD

< 2% for 0 to 100% linear load and < 5% for full non-linear load
Output Voltage Tolerance

+/- 1% static and +/- 5% at 100% load step
Bypass

Built-in static bypass

Input

Input frequency

40 – 70 Hz
Input voltage range for main operations

340 – 477V
Efficiency at Full Load

95.0 %
Input Total Harmonic Distortion

Less than 5 % for full load
Maximum Short Circuit Withstand (Icw)

30.0kAmps
Input Power Factor at Full Load

0.99

Batteries & Runtime

Battery type

External battery system
Replacement Battery

Efficiency in Battery Operation

94.0 %

Communications & Management

Interface Port(s)

DB-9 RS-232, SmartSlot
Control panel

Multifunction LCD status and control console
Audible Alarm

Alarm when on battery : distinctive low battery alarm : configurable delays
Emergency Power Off (EPO)

Yes
Available SmartSlot™ Interface Quantity

2

Physical

Maximum Height

1991MM, 199.1CM
Maximum Width

600MM, 60.0CM
Maximum Depth

1070MM, 107.0CM
Net Weight

553.0KG
Shipping weight

610.0KG
Shipping Height

2140MM, 214.0CM
Shipping Width

848MM, 84.8CM
Shipping Depth

1210MM, 121.0CM
Color

Black

Environmental

Operating Temperature

0 – 40 °C
Operating Relative Humidity

0 – 95 %
Operating Elevation

0 – 1015.9meters
Storage Temperature

-15 – 40 °C
Storage Relative Humidity

0 – 95 %
Storage Elevation

0 – 15240meters
Audible noise at 1 meter from surface of unit

63.0dBA
Online thermal dissipation

22992.0BTU/hr
Protection Class

IP20, NEMA 1

Conformance

Approvals

EN 50091-1, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, ISO 14001, ISO 9001, VFI-SS-111
Standard warranty

1 year on-site repair or replace with factory authorized Start-Up

General

Bypass Connection

5 wire (3P + N + E)
Bypass Protection Device

250.0
Max Bypass Input Current

250.0A