Shop Exclusive
Galaxy VS UPS 20kW 208V, 2 internal 9Ah smart modular battery strings, expandable to 4, Start-up 5×8 – GVSUPS20KB4FS
[ratingwidget type="page"]
-
Galaxy VS UPS 20kW 208V
- Max Configurable Power (Watts) : 20.0kWatts / 20.0kVA
- Other Input/Output Voltages : 200 V, 220 V
- Waveform type : Sine wave
- Bypass : Built-in static bypass
- Battery type : Internal modular battery, VRLA
- Part No : GVSUPS20KB4FS
For The Immediate delivery contact the sales team. Usually, Ship in 2-3 days, back order ship in 4-12 Weeks, images are for illustration purposes only.
AED 71,194.00 excl. VAT
Best Price: AED 69,414.15 on Bank Transfer / Cash Payment (-AED 1,779.85)
Estimated delivery between Nov 26, 2024 - Dec 11, 2024
Galaxy VS UPS 20kW 208V, 2 internal 9Ah smart modular battery strings, expandable to 4, Start-up 5×8 – GVSUPS20KB4FS
- Max Configurable Power (Watts) : 20.0kWatts / 20.0kVA
- Other Input/Output Voltages : 200 V, 220 V
- Waveform type : Sine wave
- Bypass : Built-in static bypass
- Battery type : Internal modular battery, VRLA
- Warranty : 1 Year
PN : GVSUPS20KB4FS
Galaxy VS UPS 20kW 208V, 2 internal 9Ah smart modular battery strings, expandable to 4, Start-up 5×8
Highly efficient, easy-to-deploy 20kW, 208V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5×8 start-up service and 2 smart high-capacity modular battery strings, expandable to 4 strings for extended runtime. Runtime charts available in the Documents tab.
Overview
Galaxy VS Features & Benefits
Total cost of Ownership
Robust operation
No power derating in kW up to 40°C or 104°F.
Wide input voltage range
Designed for harsh electrical environments to save battery life.
High efficiency in double conversion mode
Consistently high power quality at high efficiency, even at low load levels. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Compatible with Galaxy Lithium-ion Battery Cabinets
Reduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability. Galaxy VS UPSs for external batteries are compatible with Galaxy Lithium-ion Battery Cabinets.
ECOnversion mode
Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.
Compact UPS
High-density technology and full front access make this UPS a footprint saver well suited for confined spaces.
Serviceability
Modular UPS design
Provides design redundancy and fast serviceability with improved mean time to repair, via self-diagnosing, field-replaceable modules.
Multiple levels of service offers
With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like Schneider Electric to do for you.
EcoStruxure IT Expert
From your smartphone or computer, connect to our cloud-based, do-it-yourself monitoring system that collects, organizes, and distributes critical alerts and key information in real time, providing a unified view of even highly distributed physical infrastructure environments. Optimize your uptime and maintenance planning, and anticipate infrastructure issues before they occur with advanced analytics and performance benchmarking. Available in select countries. To learn more, visit a target=”_blank” href=”http://www.ecostruxureit.com”ecostruxureit.com/a.
Front-access servicing
Simplifies installation and UPS maintenance while minimizing space requirements.
Availability
Embedded Network Management Card
Allows you to remotely manage alert thresholds and monitor your UPS over EcoStruxure IT, Web, SNMP, or Modbus TCP and Modbus RTU.
Flexible DC bus
Optimizes battery sizing and supports a wide range of energy storage technologies, including VRLA, Li-ion, and NiCd batteries.
Built-in backfeed protection
Full built-in backfeed contactor ensures that no electricity is sent back to the grid.
Parallel-capacity capability
Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
Parallel-redundant capability
Powers the connected equipment with multiple uninterruptible power supplies and redundant fan design to increase system redundancy.
Published on lastbestprice.com
Detailed Tech Specification
Main |
|
Main Input Voltage | 208 V 3 phases |
Other Input Voltage | 200 V 220 V |
Main Output Voltage | 208 V 3 phases |
Other Output Voltage | 200 V 220 V |
Rated power in W | 20 kW |
Rated power in VA | 20 kVA |
Battery type | Internal modular battery VRLA |
provided equipment | Dust filter EcoStruxure IT ready (UPS) Installation guide Integrated network management Power modules ship installed Start-Up Service |
General |
|
Bypass voltage tolerance | +/- 10 % |
Redundant | No |
Physical |
|
colour | White |
Height | 148.5 cm |
Width | 52.1 cm |
Depth | 84.7 cm |
Net weight | 460 kg |
USB compatible | No |
Input |
|
Input frequency | 40-70 Hz |
Efficiency at full load | 177…239 V 208 V |
Maximum input current | 72 A |
Max short time withstand current | 65 kA |
Input harmonic distortion | Less than 3 % for full load |
Load power factor | From 0.7 leading to 0.7 lagging without any derating |
Input Power Factor at Full Load | 0.99 |
Output |
|
Maximum configurable power in W | 20 kW |
output frequency | 50 Hz sync to mains 60 Hz sync to mains 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised |
Crest factor | 2.5 |
Waveform type | Sine wave |
Output voltage tolerance | +/-1% after 50ms |
Output overload operation | 10 minutes at 125% and 60 seconds at 150% |
Bypass type | Built-in static bypass |
Maximum configurable power in VA | 20 kVA |
Conformance |
|
Standards | CSA C22.2 No 107.3 FCC Part 15 class A IEC 62040-3 IEC 60721-4-2 Level 2M2 UL 1778 5th edition |
Environmental |
|
Ambient air temperature for operation | 32…104 °F (0…40 °C) |
relative humidity | 0…95 % non-condensing |
Operating altitude | 0…3281 ft |
Ambient air temperature for storage | 5…104 °F (-15…40 °C) |
storage Relative Humidity | 0…80 % |
Storage altitude | 0…10000 ft (0.00…3048.00 m) |
Acoustic level | 61 dBA |
Heat dissipation | 4356 Btu/h |
IP degree of protection | IP20 |
Batteries & Runtime |
|
Efficiency | View Efficiency Graph
|
Battery voltage | 480V |
End of Discharge Battery Voltage | 384 V DC |
End of Discharge Maximum Battery Current | 54 A |
Battery power in VAH | 0 VAh runtime |
Extended runtime | 0 |
Communications & Management |
|
Free slots | 1 |
control panel | Touch screen LCD user interface |
alarm | Audible and visible alarms prioritized by severity |
Packing Units |
|
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 168 cm |
Package 1 Width | 99 cm |
Package 1 Length | 64 cm |
Package 1 Weight | 490 kg |
Contractual warranty |
|
Warranty | 1 year on-site repair or replace with factory authorized Start-Up |
Published on lastbestprice.com
Warranty | 1-Year |
---|
Reviews
There are no reviews yet.