APC NetShelter Rack PDU Advanced, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309 – APDU10350SW

Brand: APC

Call for Price

8 + 2 =
APC NetShelter Rack PDU Advanced
  • “Input: 3PH, 530P6”
  • “Outlets: (24) C13/C15/C19/C21, (24) C13/C15”
  • “Full-featured network management capability”
  • “Interactive LCD display”
  • “Active power measurements (volts, amps, kW, kWh)”
  • Part No : APDU10350SW
Secure Payment

Secure

Transaction

Service Center Warranty

Shop Location

WhatsApp

Call for Price

Supply Chain Alert:

Rising AI demand is causing IT supply constraints and cost increases in memory and storage, contact our specialists to secure inventory and pricing before placing orders.

Applicable to items equipped with memory and storage components.

Best Price: AED 0.00 on Bank Transfer / Cash Payment (AED 0.00)

For urgent delivery, please contact sales before ordering. Orders usually ship as per the estimated delivery date in certain case backorders may take 4–12 weeks. Images are for illustration only and may differ from the actual item.

SKU: APDU10350SW Category: Tag: Brand:

APC NetShelter Rack PDU Advanced, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309 – APDU10350SW

 


 

Overview

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2″ wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today’s high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

 

  • “Input: 3PH, 530P6”
  • “Outlets: (24) C13/C15/C19/C21, (24) C13/C15”
  • “Full-featured network management capability”
  • “Interactive LCD display”
  • “Active power measurements (volts, amps, kW, kWh)”

 

 

 

Schneider Electric APDU10350SW Picture

 

Schneider Electric APDU10350SW Picture

 

Schneider Electric APDU10350SW Picture

 

Schneider Electric APDU10350SW Picture

 

Schneider Electric APDU10350SW Picture

 

Schneider Electric APDU10350SW Picture

 

Schneider Electric APDU10350SW Picture

 

Schneider Electric APDU10350SW Picture

 

Schneider Electric APDU10350SW Picture

 

Schneider Electric APDU10350SW Picture

 

Schneider Electric APDU10350SW Picture

 

Published on lastbestprice.com

Specifications

 
Main
Colour Black
Product or component type PDU
PDU type Switched
Cord length 1.8 m
Complementary
Input Voltage 415 V 3 phases
400 V 3 phases
Height 178.0 cm
Width 5.6 cm
Output Voltage 240 V
Depth 7.5 cm
Net weight 9.6 kg
Mounting location Side
Mounting preference No preference
Input Plug Type IEC 60309 30 A 3P + N + PE
Mounting mode Rack-mounted
Rack units 0U
Mounting position Vertical
Communication port protocol 1000BASE-T
10/100BASE-T
[In] rated current 24 A
Permissible voltage 200…240 V
346…415 V
Input current limits 30 A
Load capacity 17300 VA
Network frequency 50/60 Hz
Outlet type and quantity 24 C13/C15/C19/C21
24C13/C15
Environment
Product certifications UKCA
TAA compliance
BAA compliance
Standards UL 62368-1
CSA C22.2 No 62368-1
FCC part 15 Subpart B
CE
EN 62368-1
IP degree of protection IP44
Ambient air temperature for operation -5…60 °C
Relative humidity 5…95 %
Operating altitude 0...10000 ft
Ambient air temperature for storage -25…65 °C
Storage Relative Humidity 5…95 %
Storage altitude 0…15240 m
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 198 cm
Package 1 Width 13.2 cm
Package 1 Length 26.2 cm
Package 1 Weight 12.6 kg