APC SMART-UPS RT 1000VA 230V Network Card - SURT1000XLI-NC | Price in Dubai UAE GCC

APC SMART-UPS RT 1000VA 230V Network Card – SURT1000XLI-NC

 

For Immediate delivery requirement contact sales team. Ex-Stock Usually Ship in 1 -3 days, Back to Back 4-8 Weeks. Images are for illustration purposes only and may differ from actual product.

Includes: CD with software , Smart UPS signalling RS-232 cable , User Manual

4,296.00 AED excl. VAT

Discounted Price: 4,188.60 AED on Bank Transfer / Cash Payment (-107.40 AED)

Out of stock product

0 + 2 =
SKU: SURT1000XLI-NC Categories: , Tags: ,

APC SMART-UPS RT 1000VA 230V Network Card – SURT1000XLI-NC

 

APC SMART-UPS RT 1000VA 230V Network Card

  • High density, double-conversion on-line power protection with scalable runtime

  • Includes: CD with software, Network Management Card, Smart UPS signalling RS-232 cable, User Manual

 

 

Overview

 

SURT1000XLI-NC Features

APC SMART-UPS RT 1000VA 230V Network Card
High density, double-conversion on-line power protection with scalable runtime
Includes: CD with software, Network Management Card, Smart UPS signalling RS-232 cable, User Manual

Smart-UPS On-Line Features & Benefits

Marketing Features

Save time with easy and convenient remote/network accessibility.

Network manageable via serial, USB or Ethernet. Includes Powerchute® Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
Low operating and maintenance costs with proven reliability and intelligent battery management.

Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
Avoids costly power problems by keeping your IT equipment and data protected and available.

Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
Peace of mind that comes with full equipment compatibility and reliability of a leader

Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.

Protection

Generator compatible

Ensures clean, uninterrupted power to protected equipment when generator power is used.
Cold-start capable

Provides temporary battery power when the utility power is out.
Power conditioning

Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction

Minimizes installation costs by enabling the use of smaller generators and cabling.
Frequency and voltage regulation

Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Resettable circuit breaker

Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Serviceability

Audible alarms

Provides notification of changing utility power and UPS power conditions
User-replaceable batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Predicitive failure notification

Provides early-warning fault analysis ensuring proactive component replacement.
Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Disconnected battery notification

Warns when a battery is not available to provide backup power.

Availability

Automatic restart of loads after UPS shutdown

Automatically starts up the connected equipment upon the return of utility power.
Temperature-compensated battery charging

Prolongs battery life by regulating the charge voltage according to battery temperature.
Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.
Hot-swappable batteries

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic internal bypass

Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Scalable runtime

Allows additional run time to be quickly added as needed.

Manageability

LED status indicators

Quickly understand unit and power status with visual indicators.
Serial connectivity

Provides management of the UPS via a serial port.
Network manageable

Provides remote power management of the UPS over the network.
InfraStruXure Manager Compatible

Enables centralized management via the APC InfraStruXure Manager.
SmartSlot

Customize UPS capabilities with management cards.

Adaptability

Flash upgradeable firmware

Install maintenance releases of firmware remotely using FTP.
Plug-and-Play external batteries

Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertible

Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

 

 

Detailed Tech Specification

 

Output

Output power capacity

700Watts / 1.0 kVA
Max Configurable Power (Watts)

700Watts / 1.0 kVA
Nominal Output Voltage

230V
Output Voltage Note

Configurable for 220 : 230 or 240 nominal output voltage
Output Voltage Distortion

Less than 3%
Output Frequency (sync to mains)

50/60 Hz +/- 3 Hz user adjustable +/- 0.1
Other Output Voltages

220, 240
Load Crest Factor

3 : 1
Topology

Double Conversion Online
Waveform type

Sine wave
Output Connections

(2) IEC Jumpers (Battery Backup)
(6) IEC 320 C13 (Battery Backup)
Bypass

Built-in Bypass

Input

Nominal Input Voltage

230V
Input frequency

50/60 Hz +/- 5 Hz (auto sensing)
Input Connections

IEC-320 C14
Input voltage range for main operations

160 – 280V
Input voltage adjustable range for mains operation

100 – 280V
Number of Power Cords

1
Other Input Voltages

220, 240

Batteries & Runtime

Battery type

Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time

3hour(s)
Replacement Battery

Expected Battery Life (years)

3 – 5
RBC Quantity

1
Extendable Run Time

1

Communications & Management

Interface Port(s)

DB-9 RS-232, Smart-Slot
Pre-Installed SmartSlot™ Cards

Control panel

LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators
Audible Alarm

Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Emergency Power Off (EPO)

Optional

Surge Protection and Filtering

Surge energy rating

420Joules
Filtering

Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449

Physical

Maximum Height

432mm, 43.2CM
Maximum Width

85mm, 8.5CM
Maximum Depth

483mm, 48.3CM
Rack Height

2U
Net Weight

23.0KG
Shipping weight

27.74KG
Shipping Height

286mm, 28.6CM
Shipping Width

630mm, 63.0CM
Shipping Depth

594mm, 59.4CM
Color

Black
Master Carton Units

1.0
Units per Pallet

6.0

Environmental

Operating Temperature

0 – 40 °C
Operating Relative Humidity

0 – 95 (non-condensing) %
Operating Elevation

0-3000meters
Storage Temperature

-20 – 50 °C
Storage Relative Humidity

0 – 95 (non-condensing) %
Storage Elevation

0-15000meters
Audible noise at 1 meter from surface of unit

50.0dBA
Online thermal dissipation

324.0BTU/hr
Protection Class

IP 20

Conformance

Approvals

C-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, EN 61000-3-2, GOST, VDE
Standard warranty

2 years repair or replace

Sustainable Offer Status

RoHS

Compliant
REACH

REACH: Contains No SVHCs
Battery Directive

Compliant
Other Environmental Compliance

China RoHS