Galaxy VS UPS 20kW 208V - GVSUPS20KB4FS | price in dubai uae africa saudi arabia

Galaxy VS UPS 20kW 208V, 2 internal 9Ah smart modular battery strings, expandable to 4, Start-up 5×8 – GVSUPS20KB4FS

  • Galaxy VS UPS 20kW 208V

  • Max Configurable Power (Watts) : 20.0kWatts / 20.0kVA
  • Other Input/Output Voltages : 200 V, 220 V
  • Waveform type : Sine wave
  • Bypass : Built-in static bypass
  • Battery type : Internal modular battery, VRLA
  • Part No : GVSUPS20KB4FS

 

For The Immediate delivery contact the sales team. Usually, Ship in 2-3 days, back order ship in 4-12 Weeks, images are for illustration purposes only.

AED. 71,194.00 excl. VAT

Best Price: AED. 69,414.15 on Bank Transfer / Cash Payment (-AED. 1,779.85)
Estimated delivery between Apr 30, 2024 - May 15, 2024
7 + 7 =
SKU: GVSUPS20KB4FS Category: Tags: , ,

Galaxy VS UPS 20kW 208V, 2 internal 9Ah smart modular battery strings, expandable to 4, Start-up 5×8 – GVSUPS20KB4FS

Green Premium™

 

  • Max Configurable Power (Watts) : 20.0kWatts / 20.0kVA
  • Other Input/Output Voltages : 200 V, 220 V
  • Waveform type : Sine wave
  • Bypass : Built-in static bypass
  • Battery type : Internal modular battery, VRLA
  • Warranty : 1 Year

 

PN : GVSUPS20KB4FS

 

https://download.schneider-electric.com/files?p_Doc_Ref=GVSUPS10-50KB4F-G-HS_FR_V&p_File_Type=rendition_1500_jpg

Galaxy VS UPS 20kW 208V, 2 internal 9Ah smart modular battery strings, expandable to 4, Start-up 5×8

Highly efficient, easy-to-deploy 20kW, 208V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5×8 start-up service and 2 smart high-capacity modular battery strings, expandable to 4 strings for extended runtime. Runtime charts available in the Documents tab.


 

Overview

 

Galaxy VS Features & Benefits

Total cost of Ownership

Robust operation

No power derating in kW up to 40°C or 104°F.

Wide input voltage range

Designed for harsh electrical environments to save battery life.

High efficiency in double conversion mode

Consistently high power quality at high efficiency, even at low load levels. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.

Input power factor correction

Minimizes installation costs by enabling the use of smaller generators and cabling.

Compatible with Galaxy Lithium-ion Battery Cabinets

Reduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability. Galaxy VS UPSs for external batteries are compatible with Galaxy Lithium-ion Battery Cabinets.

ECOnversion mode

Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.

Compact UPS

High-density technology and full front access make this UPS a footprint saver well suited for confined spaces.

https://download.schneider-electric.com/files?p_Doc_Ref=GVSUPS10-50KB4F-G-HS_FL_V&p_File_Type=rendition_1500_jpg

Serviceability

Modular UPS design

Provides design redundancy and fast serviceability with improved mean time to repair, via self-diagnosing, field-replaceable modules.

Multiple levels of service offers

With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like Schneider Electric to do for you.

EcoStruxure IT Expert

From your smartphone or computer, connect to our cloud-based, do-it-yourself monitoring system that collects, organizes, and distributes critical alerts and key information in real time, providing a unified view of even highly distributed physical infrastructure environments. Optimize your uptime and maintenance planning, and anticipate infrastructure issues before they occur with advanced analytics and performance benchmarking. Available in select countries. To learn more, visit a target=”_blank” href=”http://www.ecostruxureit.com”ecostruxureit.com/a.

Front-access servicing

Simplifies installation and UPS maintenance while minimizing space requirements.

 

Availability

Embedded Network Management Card

Allows you to remotely manage alert thresholds and monitor your UPS over EcoStruxure IT, Web, SNMP, or Modbus TCP and Modbus RTU.

Flexible DC bus

Optimizes battery sizing and supports a wide range of energy storage technologies, including VRLA, Li-ion, and NiCd batteries.

Built-in backfeed protection

Full built-in backfeed contactor ensures that no electricity is sent back to the grid.

Parallel-capacity capability

Increases total power capacity by using multiple uninterruptible power supplies simultaneously.

Parallel-redundant capability

Powers the connected equipment with multiple uninterruptible power supplies and redundant fan design to increase system redundancy.

https://download.schneider-electric.com/files?p_Doc_Ref=GVSUPS10-50KB4F-G-HS_B_V&p_File_Type=rendition_1500_jpg

 

Published on lastbestprice.com

 

Detailed Tech Specification

 

Main

Main Input Voltage 208 V 3 phases
Other Input Voltage 200 V
220 V
Main Output Voltage 208 V 3 phases
Other Output Voltage 200 V
220 V
Rated power in W 20 kW
Rated power in VA 20 kVA
Battery type Internal modular battery
VRLA
provided equipment Dust filter
EcoStruxure IT ready (UPS)
Installation guide
Integrated network management
Power modules ship installed
Start-Up Service

 

General

Bypass voltage tolerance +/- 10 %
Redundant No

 

Physical

colour White
Height 148.5 cm
Width 52.1 cm
Depth 84.7 cm
Net weight 460 kg
USB compatible No

 

Input

Input frequency 40-70 Hz
Efficiency at full load 177…239 V 208 V
Maximum input current 72 A
Max short time withstand current 65 kA
Input harmonic distortion Less than 3 % for full load
Load power factor From 0.7 leading to 0.7 lagging without any derating
Input Power Factor at Full Load 0.99

 

Output

Maximum configurable power in W 20 kW
output frequency 50 Hz sync to mains
60 Hz sync to mains
60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised
50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised
Crest factor 2.5
Waveform type Sine wave
Output voltage tolerance +/-1% after 50ms
Output overload operation 10 minutes at 125% and 60 seconds at 150%
Bypass type Built-in static bypass
Maximum configurable power in VA 20 kVA

 

Conformance

Standards CSA C22.2 No 107.3
FCC Part 15 class A
IEC 62040-3
IEC 60721-4-2 Level 2M2
UL 1778 5th edition

 

Environmental

Ambient air temperature for operation 32…104 °F (0…40 °C)
relative humidity 0…95 % non-condensing
Operating altitude 0…3281 ft
Ambient air temperature for storage 5…104 °F (-15…40 °C)
storage Relative Humidity 0…80 %
Storage altitude 0…10000 ft (0.00…3048.00 m)
Acoustic level 61 dBA
Heat dissipation 4356 Btu/h
IP degree of protection IP20

 

Batteries & Runtime

Efficiency View Efficiency Graph

 

Battery voltage 480V
End of Discharge Battery Voltage 384 V DC
End of Discharge Maximum Battery Current 54 A
Battery power in VAH 0 VAh runtime
Extended runtime 0

 

Communications & Management

Free slots 1
control panel Touch screen LCD user interface
alarm Audible and visible alarms prioritized by severity

 

Packing Units

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 168 cm
Package 1 Width 99 cm
Package 1 Length 64 cm
Package 1 Weight 490 kg

 

Contractual warranty

Warranty 1 year on-site repair or replace with factory authorized Start-Up

 

Published on lastbestprice.com
Warranty

1-Year