Rack PDU 2G Metered by Outlet with Switching ZeroU 16A 230V - AP8659EU3 | price in dubai UAE Africa saudi arabia

Rack PDU 2G Metered by Outlet with Switching ZeroU 16A 230V (21) C13 & (3) C19 – AP8659EU3

For The Immediate delivery contact the sales team. Usually, Ship in 2-3 days, back order ship in 4-12 Weeks, images are for illustration purposes only.

Call for Price

Best Price: AED. 0.00 on PayPal / Cash Payment (AED. 0.00)
0 + 9 =
SKU: AP8659EU3 Category: Tag:

Rack PDU 2G Metered by Outlet with Switching ZeroU 16A 230V (21) C13 & (3) C19 – AP8659EU3

 

 

Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 16A, 230V, (21) C13 & (3) C19

 

 

Overview

 

AP8659EU3 Features

Output Connections

(3) IEC 60320 C19
(21) IEC 60320 C13
Nominal Output Voltage

230V
Nominal Input Voltage

200V, 208V, 230V
Input Connections

IEC 60309 16 A 2P + E
Cord Length

3meters

Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 16A, 230V, (21) C13 & (3) C19

APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
Includes: CAN port terminator, Installation guide, Locking input power cord, Rack mounting brackets, Safety guide, Serial configuration cable
  • Metering-by-Outlet capability
    Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.

NetShelter Metered-by-Outlet with Switching Rack PDU Features & Benefits

Availability

Flash Upgradeable

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Network Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Metering-by-Outlet capability

Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.
Remote Individual Outlet Control

Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Outlet Power Sequencing

Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
Local Current Monitoring Display

The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Load indicator LED

Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. (Note: Only available with units with local current monitoring feature)
Integrates with StruxureWare Data Center Expert

An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Agility

Single input power source

Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 16A, 230V, (21) C13 & (3) C19

 

 

Detailed Tech Specification

 

Output

Overload Protection

No
Maximum Total Current Draw

16

Input

Input frequency

50/60 Hz
Acceptable Input Voltage

100 – 240VAC
Load Capacity

3700VA
Maximum Input Current

16A

Physical

Maximum Height

1829MM, 182.9CM
Maximum Width

56MM, 5.6CM
Maximum Depth

51MM, 5.1CM
Net Weight

6.77KG
Shipping weight

9.05KG
Shipping Height

2038MM, 203.8CM
Shipping Width

162MM, 16.2CM
Shipping Depth

117MM, 11.7CM
Color

Black

Environmental

Operating Temperature

-5 – 60 °C
Operating Relative Humidity

5 – 95 %
Operating Elevation

0 – 3048meters
Storage Temperature

-25 – 65 °C
Storage Relative Humidity

5 – 95 %
Storage Elevation

0 – 15240meters

Conformance

Approvals

EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC part 15 class A, ICES-003, PSE, UL listed, VCCI class A, VDE
Standard warranty

2 years repair or replace

Sustainable Offer Status

RoHS

Compliant