Rack PDU 2G Metered ZeroU 22.0kW(32A) 230V (30) C13 & (12) C19 – AP8886

For The Immediate delivery contact the sales team. Usually, Ship in 2-3 days, back order ship in 4-12 Weeks, images are for illustration purposes only.

Call for Price

Best Price: AED. 0.00 on PayPal / Cash Payment (AED. 0.00)
4 + 9 =
SKU: AP8886 Category: Tags: ,

Rack PDU 2G Metered ZeroU 22.0kW(32A) 230V (30) C13 & (12) C19 – AP8886

RoHS

 

 

Rack PDU 2G, Metered, ZeroU, 22.0kW(32A) 17.3kW(24A), 230V, (30) C13 & (12) C19

 

 

Overview

 

AP8886 Features

Output Connections

(30) IEC 60320 C13
(12) IEC 60320 C19

Nominal Output Voltage

230V

Nominal Input Voltage

400V 3PH

Input Connections

IEC 60309 32 A 3P + N + E

Cord Length

1.8meters
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A) 17.3kW(24A), 230V, (30) C13 & (12) C19

Rack PDU 2G, Metered, ZeroU, 22.0kW(32A) 17.3kW(24A), 230V, (30) C13 & (12) C19

APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Includes: Installation guide, Rack mounting brackets, Safety guide, Serial configuration cable

NetShelter Metered Rack PDUs Features & Benefits

Agility

Rack-Mountable

Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most – in the racks near the equipment.

Single input power source

Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Wide range of input and output connections

Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 17.3kW using a single branch whip.

Availability

60C Operating Temperature

All 8000 and 9000 series PDUs now provide the ability to operate in a maximum ambient air temperature of 60C (140F) at full load ensuring reliability and availability even in today’s high density deployments. Other models allow up to 45C (113F).

Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Load indicator LED

Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Local Current Monitoring Display

The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Flash Upgradeable

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Integrates with StruxureWare Data Center Expert

An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Remote Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Command Line Interface. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Marketing features

Local Current Monitoring Display

The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A) 17.3kW(24A), 230V, (30) C13 & (12) C19

Detailed Tech Specification

 

Output

Overload Protection

Yes

Maximum Total Current Draw

32

Input

Input frequency

50/60 Hz

Load Capacity

22000VA

Maximum Input Current

32A

Maximum Line Current

32A

Physical

Maximum Height

1829MM, 182.9CM

Maximum Width

56MM, 5.6CM

Maximum Depth

51MM, 5.1CM

Net Weight

8.72KG

Shipping weight

11.55KG

Shipping Height

2050MM, 205.0CM

Shipping Width

170MM, 17.0CM

Shipping Depth

112MM, 11.2CM

Color

Black

Environmental

Operating Temperature

-5 – 60 °C

Operating Relative Humidity

5 – 95 %

Operating Elevation

0 – 3048meters

Storage Temperature

-25 – 65 °C

Storage Relative Humidity

5 – 95 %

Storage Elevation

0 – 15240meters

Conformance

Approvals

EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC part 15 class A, ICES-003, VCCI class A, VDE

Standard warranty

2 years repair or replace

Sustainable Offer Status

RoHS

Compliant