Rack PDU 2G, Switched, ZeroU, 8.6kW, 208V, (21) C13 & (3) C19, 12ft Cord – AP8965X633

 

 

Overview

 

AP8965Features

RACK PDU 2G, SWITCHED, ZEROU, 8.6kW, 208V, (21) C13 & (3) C19

APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing time delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.

Includes : Installation guide , Rack Mounting brackets , Safety guide , Serial configuration cable

Switched Rack PDUFeatures & Benefits

Manageability
  • Remote Individual Outlet Control
    Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
  • Network Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
  • Multi-tier user access
    Supports up to four access levels – Administrator, Device User, Read-Only User and Network-only User – with user name and password requirements.
  • Local Current Monitoring Display
    The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
  • Network port sharing
    Allows four rack PDUs to be connected using In and Out ports so that only one network connection is necessary.
  • Integrates with StruxureWare Data Center Expert
    An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
  • Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
  • Power Delays
    Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Marketing Features
  • Power Delays
    Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
  • Remote Individual Outlet Control
    Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
  • Remote Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
  • Local Current Monitoring Display
    The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Adaptability
  • Rack-Mountable
    Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most – in the racks near the equipment.
  • Single input power source
    Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
  • Wide range of input and output connections
    Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

 

Detailed Tech Specification

 

Output

  • Nominal Output Voltage

    208V

  • Overload Protection

    Yes

  • Maximum Total Current Draw

    30

  • Output Connections
    (21) IEC 320 C13 (Battery Backup)
    (3) IEC 320 C19 (Battery Backup)

Input

  • Nominal Input Voltage

    208V 3PH

  • Input frequency

    50/60 Hz

  • Input Connections

    NEMA L21-30P

  • Cord Length

    1.83meters

  • Number of Power Cords

    1

  • Maximum Input Current

    30A

  • Maximum Line Current

    30A

  • Regulatory Derated Input Current (North America)

    24A

Physical

  • Maximum Height

    1829mm , 182.9CM

  • Maximum Width

    56mm , 5.6CM

  • Maximum Depth

    51mm , 5.1CM

  • Net Weight

    8.18KG

  • Shipping weight

    10.32KG

  • Shipping Height

    2040mm , 204.0CM

  • Shipping Width

    165mm , 16.5CM

  • Shipping Depth

    124mm , 12.4CM

  • Color

    Black

  • Units per Pallet

    48.0

Environmental

  • Operating Temperature

    -5 – 45 °C

  • Operating Relative Humidity

    5 – 95 %

  • Operating Elevation

    0-3000meters

  • Storage Temperature

    -25 – 65 °C

  • Storage Relative Humidity

    5 – 95 %

  • Storage Elevation

    0-15000meters

Conformance

  • Approvals

    cUL Listed, FCC Part 15 Class A, ICES-003, UL Listed, VCCI Class A

  • Standard warranty

    2 years repair or replace