Key Applications
- Enterprise Server
- Database Processing & Storage
- Appliance Optimized Storage
Key Features
- Single Socket P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable processors. Up to 270W TDP.
- 8 DIMMs; Supports 3DS DDR4-3200: RDIMM/LRDIMM/Intel® DCPMM
- 2 PCIe 4.0 x16 (LP) slots, 2 PCIe 4.0 x8 (LP) slots
- Intel® Ethernet Controller X550 2x 10GbE RJ45
- 36x Hot-swap 3.5″ SAS3/SATA3 drive bays (24 front + 12 rear), Onboard 1x NVMe/SATA M.2; 2x Hot-swap 2.5″ NVMe/SATA (rear, optional); 2x Internal fixed bay support up to 4x 2.5″ drive bays (optional)
- Redundant Titanium 1200W Power Supply
AED 38,580.00 excl. VAT
Best Price: AED 37,615.50 on Bank Transfer / Cash Payment (-AED 964.50)
Available on backorder
Estimated delivery between Jan 21, 2025 - Feb 3, 2025
SuperMicro UP Storage SuperServer SSG-540P-E1CTR36H 36Bay NAS Storage – 200TB
Configuration:
36Bay NAS Storage – 200TB | |
SSG-540P-E1CTR36H | SSG-540P, 4U, Single CPU, Intel Xeon Silver 4310 Processor 12-Core 2.1GHz 18MB Cache (120W), 2x32GB DDR4 1.2V 3200 ECC REG, Broadcom 3916 RAID COntroller (0,1,10,5,6,10,50,60 support) 2x 960GB, SATA 2.5″ 1.5DWPD, 10x Seagate 3.5″, 20TB, 7.2K RPM, SAS3 12Gb/s, Cache 256MB, 512e/4Kn (LongsPeak) 2x 10GbE, 1x GbE IPMI, Dual 800 watts RPS, 3 Years warranty, no OS |
Specifications:
Product SKUs | |
SuperServer SSG-540P-E1CTR36H (Black) | |
Motherboard | |
Super X12SPI-TF | |
Processor | |
CPU | Single Socket P+ (LGA-4189) |
3rd Gen Intel® Xeon® Scalable processors | |
Core Count | Up to 40C/80T; Up to 60MB Cache per CPU |
Note | Supports up to 270W TDP CPUs (Air Cooled) |
System Memory | |
Memory | Memory Capacity: 8 DIMM slots |
Up to 2TB: 8x 256 GB DRAM | |
Up to 3TB: 4x 256 GB DRAM and 4x 512 GB PMem | |
Memory Type: 3200/2933/2666MHz ECC DDR4 RDIMM;LRDIMM | |
Intel® Optane™ persistent memory 200 series | |
Memory Voltage | 1.2 V |
Error Detection | Yes |
On-Board Devices | |
SATA | SATA3 (6Gbps) via C621A Chipset; RAID 0, 1, 5, 10 support |
SAS | SAS3 (12Gbps) via Broadcom 3908; RAID 0, 1, 5, 6, 10, 50, 60 support |
Chipset | Intel® C621A |
Network Connectivity | 2x 10GbE BaseT with Intel® X550 |
IPMI | Support for Intelligent Platform Management Interface v.2.0 |
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support | |
Input / Output | |
LAN | 1 RJ45 Dedicated IPMI LAN port |
2 RJ45 10GBase-T LAN ports | |
USB | 4 USB 2.0 port(s) (2 headers; 2 rear) |
5 USB 3.2 Gen 1 port(s) (2 headers; 2 rear; 1 Type A) | |
Video | 1 VGA port(s) |
Serial Port | 1 COM Port(s) (1 header) |
DOM | 2 SuperDOM (Disk on Module) port with built-in power |
System BIOS | |
BIOS Type | AMI 32MB SPI Flash EEPROM |
Management | |
Software | IPMI 2.0 |
KVM with dedicated LAN | |
Super Diagnostics Offline | |
SuperDoctor® 5 | |
Supermicro Update Manager (SUM) | |
Supermicro Power Manager (SPM) | |
Supermicro Server Manager (SSM) | |
Redfish API | |
Power Configurations | ACPI/APM Power Management |
Security | |
Hardware | Trusted Platform Module (TPM) 2.0 |
Silicon Root of Trust (RoT) – NIST 800-193 Compliant | |
Features | Cryptographically Signed Firmware |
Secure Boot | |
Secure Firmware Updates | |
Automatic Firmware Recovery | |
System Lockdown | |
PC Health Monitoring | |
CPU | 7+1 Phase-switching voltage regulator module (VRM) |
Monitors for CPU Cores, Chipset Voltages, Memory | |
FAN | Fans with tachometer monitoring |
Pulse Width Modulated (PWM) fan connectors | |
Status monitor for speed control | |
Temperature | Monitoring for CPU and chassis environment |
Thermal Control for fan connectors |
Chassis | |||||||||||
Form Factor | 4U Rackmount | ||||||||||
Model | CSE-847BTS-R1K23LPBP4 | ||||||||||
Dimensions and Weight | |||||||||||
Height | 7″ (178mm) | ||||||||||
Width | 17.2″ (437mm) | ||||||||||
Depth | 27.5″ (699mm) | ||||||||||
Package | 17.5″ (H) x 27″ (W) x 39.5″ (D) | ||||||||||
Weight | Net Weight: 66.5 lbs (29.7 kg) | ||||||||||
Gross Weight: 102.5 lbs (46.4 kg) | |||||||||||
Available Color | Black | ||||||||||
Front Panel | |||||||||||
Buttons | Power On/Off | ||||||||||
System Reset | |||||||||||
LEDs | Device Activity | ||||||||||
LAN 1 Activity | |||||||||||
LAN 2 Activity | |||||||||||
Power Failure LED | |||||||||||
Power status | |||||||||||
System information | |||||||||||
Expansion Slots | |||||||||||
PCI-Express (PCIe) | 2 PCIe 4.0 x8 LP slot(s) | ||||||||||
2 PCIe 4.0 x16 LP slot(s) | |||||||||||
Drive Bays / Storage | |||||||||||
Hot-swap | 36x 3.5″ hot-swap SATA/SAS drive bays | ||||||||||
M.2 | 1x PCIe 3.0 x4 and SATA | ||||||||||
Form Factor: 2280, 22110 | |||||||||||
Key: M-key | |||||||||||
Peripheral Bays | 2x 2.5″ SATA or NVMe drive bays (optional) | ||||||||||
System Cooling | |||||||||||
Fans | 7x (8cm x8cm x3.8cm) heavy duty fans with optimal fan speed control | ||||||||||
Air Shroud | 1 Air Shroud(s) | ||||||||||
Power Supply | |||||||||||
1200W Redundant Titanium Level power supplies | |||||||||||
Dimension | 76 x 40 x 336 mm | ||||||||||
(W x H x L) | |||||||||||
AC Input | 1000W: 100-127Vac / 50-60Hz | ||||||||||
1200W: 200-240Vac / 50-60Hz | |||||||||||
1200W: 200-240Vdc / 50-60Hz (for CCC only) | |||||||||||
+12V | Max: 83A / Min: 0A (100Vac-127Vac) | ||||||||||
Max: 100A / Min: 0A (200Vdc-240Vdc) | |||||||||||
Max: 100A / Min: 0A (200Vac-240Vac) | |||||||||||
5V SB | Max: 4A / Min: 0A | ||||||||||
Output Type | Backplanes (gold finger) | ||||||||||
Certification |
|
||||||||||
[ Test Report ] | |||||||||||
Operating Environment | |||||||||||
Environmental Spec. | Operating Temperature: | ||||||||||
10°C ~ 35°C (50°F ~ 95°F) | |||||||||||
Non-operating Temperature: | |||||||||||
-40°C to 70°C (-40°F to 158°F) | |||||||||||
Operating Relative Humidity: | |||||||||||
8% to 90% (non-condensing) | |||||||||||
Non-operating Relative Humidity: | |||||||||||
5% to 95% (non-condensing) |
Standard Parts (Parts Included) |
|||
Part Number | Qty | Description | |
Motherboard / Chassis | MBD-X12SPI-TF
CSE-847BTS-R1K23LPBP4 |
1
1 |
Super X12SPI-TF Motherboard
4U Chassis |
Add-on Card / Module | AOC-S3908L-H8IR-P | 1 | 8 int 12Gb/s ports, x8 Gen4, ROC- LP, 240 HDD w/exp,RoHS |
AOM-SAS3-8I8E-LP | 1 | 8-port Mini SAS HD Int-to-Ext Cable Adapter W/LP Bracket | |
Backplane | BPN-SAS3-826EL1-N4 | 1 | 12-Port 2U Backplane with Expander support up to 8 x 3.5″ SAS3/SATA3 HDD/SDD and 4 x SAS3/SATA3/NVMe Storage Devices,HF,RoHS/REACH |
BPN-SAS3-846EL1 | 1 | 24-port 4U SAS3 12Gbps single-expander backplane, support up to 24x 3.5-inch SAS3/SATA3 HDD/SSD | |
Cable | CBL-0296L | 4 | 9″ 4 PIN FAN PWS EXTENSION CORD, PBF |
CBL-CDAT-0728 | 1 | 4 Pin to 4 Pin I2C Cable, 65cm, 26AWG, 4 Wires, Pinout 1-1 | |
CBL-SAST-1264-100 | 1 | Slimline x8 (STR) to 2x MiniSAS HD x4,65CM,100 OHM,RoHS | |
CBL-SAST-0531 OR | 4 | Internal Mini-SAS HD to Mini-SAS HD 80cm,30AWG,12Gb/s | |
CBL-SAST-0531-01 | Internal Mini-SAS HD to Mini-SAS HD 80cm,30AWG,12Gb/s [FCI] | ||
CBL-0071L | 1 | ROUND 16 TO 16 PIN RIBBON FP CABLE 30″L, LF | |
CBL-0160L | 2 | US POWER CORD 16AWG, PB FREE | |
CBL-PWEX-1079 | 7 | PWEX,FAN,1X4/P2.5 TO 1X4/P2.54,37CM,22AWG,5A/pin,RoHS | |
Parts | MCP-260-00042-1N | 1 | Standard I/O Shield for X12SPi with EMI Gasket |
Manual | MNL-2360-QRG | 1 | 540P-E1CTR36L/H Quick Reference Guide |
Software | SFT-OOB-LIC | 1 | License key for enabling OOB BIOS management |
Heatsink / Retention | SNK-P0078P | 1 | 2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms |
*Power Supply | PWS-1K23A-1R | 2 | AC-DC 1200W, Titanium Level, Redundancy, 1U, PMBUS 1.2, +12V/+5Vsb, 336x76x40 mm,HF,RoHS/REACH |
*Power Distributor | PDB-PT847-8824 | 1 | 24pin standard output with 5V high current 100Amp power distributor board for SC847 |
*Fan | FAN-0166L4 | 7 | 80x80x38 mm, 13.5K RPM, Optional Middle Cooling Fan for 2U Ultra Series Servers (Hot-swappable Version of FAN-0162L4) |
*Front Panel | FPB-TB826-T | 1 | Chassis transfer board for SC826 |
*Drive Tray(s) | MCP-220-00075-0B | 36 | Black gen 5.5 hot-swap 3.5″ HDD tray |
MCP-220-84708-ASM | 1 | SC847B LP MB Tray assembly,HF,RoHS/REACH | |
*Rail Set | MCP-290-00057-0N | 1 set | Rail set, quick/quick, default for 4U 17.2″ W |
MCP-410-00007-0N | 1 | Rail screw bag | |
*Air Shroud | MCP-310-49004-0N | 1 | SC847/417 DP X9 universal PC air shroud 1368×13/12x13MB |
Notes:
|
Optional Parts List | |||
Part Number | Qty | Description | |
2x 2.5″ NVMe Cage (Rear) | MCP-220-82619-0N + 1x CBL-SAST-1264-85 | 1 | Rear hot-swap 2x 2.5″ NVMe drive kit |
2x 2.5″ SATA/SAS Cage (Rear) | MCP-220-82616-0N • | 1 | Rear hot-swap 2x 2.5″ SATA/SAS drive kit |
3.5″ to 2.5″ Converter Tray(s) | MCP-220-00043-0N • | – | Hot-swap Gen-4 3.5″ to 2.5″ HDD tray, Black |
CacheVault | BTR-CVPM05 & BKT-BBU-BRACKET-05 (For S3908) | 1 | CacheVault for Broadcom 3908 with SuperCap mounting bracket for PCIe location |
Intel VROC RAID Key for NVMe | AOC-VROCPREMOD • | 1 | Premium Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10/5 |
AOC-VROCSTNMOD | 1 | Standard Upgrade module (Intel + 3rd party Vendor SSD); RAID 0/1/10 | |
AOC-VROCINTMOD | 1 | Intel SSD Only Upgrade module; RAID 0/1/10/5 | |
Software | SFT-DCMS-Single | 1 | DataCenter Management Package (per node license) |
TPM | AOM-TPM-9670V-S-O | 1 | TPM 2.0, vertical form factor, provisioned for server |
AOM-TPM-9671V-S-O | 1 | TPM 1.2, vertical form factor, provisioned for server |