Shop Exclusive
APC Smart-UPS VT 20kVA 400V w/2 Batt Mod., Start-Up 5X8, Int Maint Bypass, Parallel Capable – SUVTP20KH2B2S
Brand: APC
Call for Price
⚠ Product Discontinued On: 05-July-2021
⚠ End-of-Service On: 31-December-2030
Out of stock product
[ratingwidget type="page"]
Call for Price
Best Price: AED 0.00 on Bank Transfer / Cash Payment (AED 0.00)
For urgent delivery, please contact sales before ordering. Orders usually ship as per the estimated delivery date in certain case backorders may take 4–12 weeks. Images are for illustration only and may differ from the actual item.
APC Smart-UPS VT 20kVA 400V w/2 Batt Mod., Start-Up 5X8, Int Maint Bypass, Parallel Capable – SUVTP20KH2B2S
Overview
SUVTP20KH2B2S Features
APC Smart-UPS VT 20kVA 400V w/2 Batt Mod., Start-Up 5X8, Int Maint Bypass, Parallel Capable
-
Parallel-capacity capableIncreases total power capacity by using multiple uninterruptible power supplies simultaneously.
-
Parallel-redundant capablePower the connected equipment with multiple uninterruptible power supplies to increase system redundancy
Smart-UPS VT Features & Benefits
Marketing Features
-
Scalable runtimeAllows additional run time to be quickly added as needed.
-
Dual mains inputIncreases availability by allowing the UPS to be connected to two separate power sources.
-
Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.
-
Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced
-
Manual maintenance bypassReduces installation costs by eliminating the need for an external mechanical bypass.
-
Network manageableProvides remote power management of the UPS over the network.
Serviceability
-
Modular designProvides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
-
Battery replacement without toolsEnables fast battery replacement, lowering Mean Time to Repair (MTTR).
-
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
-
Shippable with modules installedEnables pre-installation UPS staging and testing and faster installation.
Total Cost of Ownership
-
Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.
-
Manual maintenance bypassReduces installation costs by eliminating the need for an external mechanical bypass.
-
Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
-
Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.
Availability
-
Battery modules connected in parallelDelivers higher availability through redundant batteries.
-
Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.
-
Dual mains inputIncreases availability by allowing the UPS to be connected to two separate power sources.
-
Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS power overload or fault.
-
Scalable runtimeAllows additional run time to be quickly added as needed.
Manageability
-
Audible alarmsProvides notification of changing utility power and UPS power conditions
-
Network manageableProvides remote power management of the UPS over the network.
-
LCD displayAlpha-Numeric Display which displays system parameters and alarms.
-
InfraStruXure Manager CompatibleEnables centralized management via the APC InfraStruXure Manager.
-
Programmable frequencyEnsures compatibility with different input frequencies.
-
LED status indicatorsQuickly understand unit and power status with visual indicators.
-
SmartSlotCustomize UPS capabilities with management cards.
Sustainability
-
EU CoC for UPSEnsures that UPSs sold in the EU are highly efficient
Protection
-
Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
-
Frequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.
-
Cold-start capableProvides temporary battery power when the utility power is out.
Detailed Tech Specifications
Output
-
Output power capacity
16.0 KWatts / 20.0 kVA
-
Max Configurable Power (Watts)
16.0 KWatts / 20.0 kVA
-
Nominal Output Voltage
400V 3PH
-
Output Voltage Note
Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
-
Efficiency at Full Load
95.3 %
-
Output Voltage Distortion
Less than 5% at full load
-
Output Frequency (sync to mains)
47 – 53 Hz for 50 Hz nominal
-
Output Frequency (not synced)
50Hz +/- 0.1% for 50Hz nominal
-
Other Output Voltages
380, 415
-
Load Crest Factor
3 : 1
-
Topology
Double Conversion Online
-
Waveform type
Sine wave
-
Maximum Output Current
32
-
Output Connections(1) Hard Wire 4-wire (3PH + G) (Battery Backup)(1) Hard Wire 5-wire (3PH + N + G) (Battery Backup)(1) Screw Terminals (Battery Backup)
-
Bypass
Built-in Maintenance Bypass, Built-in Static Bypass
Input
-
Nominal Input Voltage
400V 3PH
-
Input frequency
40 – 70 Hz (auto sensing)
-
Input Connections
Hard Wire 5-wire (3PH + N + G)
-
Input voltage range for main operations
304 – 477V
-
Efficiency at Full Load
95.3 %
-
Other Input Voltages
380, 415
-
Maximum Input Current
27.0A
-
Input Power Factor at Full Load
0.98
Batteries & Runtime
-
Battery type
VRLA
-
Included Battery Modules
2
-
Typical recharge time
5hour(s)
-
Nominal Battery Voltage
+/-192 V (split battery referenced to neutral)
-
Expected Battery Life (years)
3 – 5
-
RBC Quantity
2
-
Extendable Run Time
1
-
Extended Run Options
APC-Smart-UPS-VT-20kVA-400V-w-2-Batt-Mod-Start-Up-5X8-Int-Maint-Bypass-Parallel-Capable
-
End of Discharge Battery Voltage
+/-154 V
-
Runtime
Communications & Management
-
Interface Port(s)
DB-9 RS-232 , Smart-Slot
-
Pre-Installed SmartSlot™ Cards
-
Control panel
Multi-function LCD status and control console
-
Audible Alarm
Audible and visible alarms prioritized by severity
-
Emergency Power Off (EPO)
Yes
Physical
-
Maximum Height
1490mm , 149.0cm
-
Maximum Width
352mm , 35.2cm
-
Maximum Depth
842mm , 84.2cm
-
Net Weight
396.82kg
-
Shipping weight
428.18kg
-
Shipping Height
1643mm , 164.3cm
-
Shipping Width
650mm , 65.0cm
-
Shipping Depth
1062mm , 106.2cm
-
Color
Black
-
Units per Pallet
1.0
Environmental
-
Operating Environment
0 – 40 °C
-
Operating Relative Humidity
0 – 95 %
-
Operating Elevation
0-999.9meters
-
Storage Temperature
-50 – 40 °C
-
Storage Relative Humidity
0 – 95 %
-
Storage Elevation
0-15000meters
-
Audible noise at 1 meter from surface of unit
64.0dBA
-
Online thermal dissipation
3112.0BTU/hr
-
Protection Class
IP 20
Conformance
-
Approvals
C-tick, CE, EN 50091-2, EN/IEC 62040-3, IEC 61000-3-2, IEC 61000-3-3, ISO 14001, ISO 9001, RCM, VFI-SS-111
-
Standard warranty
1 year repair or replace, Start-Up Service

















Reviews